• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Habilitation Thesis
DOI
https://doi.org/10.11606/T.3.2011.tde-02062022-081052
Document
Author
Full name
Flávio Augusto Sanzovo Fiorelli
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Committee
Yanagihara, Jurandir Itizo (President)
Altemani, Carlos Alberto Carrasco
Oliveira Junior, Silvio de
Parise, José Alberto dos Reis
Seleghim Junior, Paulo
Title in Portuguese
Ciclo de refrigeração por compressão de vapor: análise do escoamento metaestável em tubos capilares
Keywords in Portuguese
Escoamento metaestável
Refrigeração
Tubos capilares
Abstract in Portuguese
O escoamento metaestável de fluido refrigerante em tubos capilares é um fenômeno que ocorre freqüentemente nesse tipo de dispositivo de expansão, sendo responsável por aumentar o comprimento total de escoamento de líquido e a vazão mássica que escoa pelo tubo, afetando o desempenho desse componente do sistema de refrigeração por compressão de vapor. Portanto, a incorporação de correlações para previsão da ocorrência do fenômeno em modelos de simulação deve ser considerada. No presente trabalho foi realizado estudo experimental da ocorrência do escoamento metaestável de R-410A em tubos capilares adiabáticos, no qual se analisou o efeito dos principais parâmetros geométricos e operacionais no atraso de vaporização Δpsat e no comprimento do trecho de escoamento metaestável Lms. Os ensaios mostraram que existem tendências de variação bastante definidas para Δpsat e Lms, mesmo se for levada em conta a aleatoriedade dos dados experimentais. Esse fato permite concluir que o fenômeno da metaestabilidade, embora não possa ser bem representado pontualmente, pode ser adequadamente estudado de forma média, possibilitando a previsão de Δpsat e Lms. Os resultados experimentais foram a seguir utilizados para adequar uma correlação para previsão do atraso de vaporização previamente desenvolvida às condições do presente trabalho. O erro médio obtido na previsão do atraso de vaporização com a correlação obtida é de 21,8% e o modelo prevê 82% dos valores experimentais dentro da faixa de ±30,0%, que é um resultado semelhante ao de outros trabalhos da literatura.A correlação obtida foi então incorporada ao modelo de simulação de tubos capilares desenvolvido pelo autor, e os resultados da nova validação indicam que, para os tubos capilares com diâmetros de 1,089 e 1,381 mm, a incorporação praticamente elimina a diferença observada entre os valores experimentais e calculados quando esse efeito não é considerado. Já para o tubo de maior diâmetro (1,643 mm), as diferenças situam-se na faixa de +2,0 a +5,0% para a maioria dos casos. Dessa forma, pode-se concluir que, mesmo que se tenha verificado um erro relativamente elevado da correlação para previsão do atraso de vaporização, o modelo modificado de simulação de tubos capilares representa mais adequadamente o desempenho do componente com a incorporação da correlação obtida.
Title in English
Vapor compression refrigerating systems: analysis of metastable flow in capillary tubes.
Keywords in English
Capillary tubes
Metastable flow
Refrigeration
Abstract in English
Refrigerant fluid metastable flow is a frequent phenomenon that occurs in capillary tubes. Such phenomenon increases liquid flow region length and mass flow rates, affecting the performance of this component of the vapor compression refrigeration cycle, and it is important to include correlations for predicting its occurrence in simulation models. This work presents an experimental study on the metastable flow of R-410A in adiabatic capillary tubes. The effect of main geometrical and operational parameters on the delay of vaporization Δpsat and metastable flow region length Lms is analyzed. Experimental results show that besides the randomness of the data, there are well-defined tendencies for Δpsat and Lms variations. This fact leads to conclude that the metastability phenomenon can be adequately analyzed in an average way, which allows predicting Δpsat and Lms. Experimental data were then used to modify a previously developed correlation for predicting delay of vaporization to present work conditions. The average error of obtained correlation is 21.8% and it predicts 82% of experimental results within a ±30.0% range, a similar result to other works. Obtained correlation was also included in a capillary tubes simulation model developed by the author, and the new validation of the model indicates that for capillary tubes of 1.089 and 1.381 mm inner diameter the inclusion nearly eliminates the difference between experimental and simulation data observed when this phenomenon is not taken into account. For capillary tube of 1.643 mm, difference ranges from +2.0 to +5.0% for most of the cases. This result indicates that despite the relatively high error of delay of vaporization predicting correlation, the capillary tube simulation model including such correlation more adequately represents the performance of this component of the refrigeration cycle.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2022-06-02
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.