• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2023.tde-21062023-154456
Documento
Autor
Nombre completo
José Roberto Berretta
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2023
Director
Tribunal
Mesquita, Carlos Henrique de (Presidente)
Dantas, Carlos Costa
Madi Filho, Tufic
Pereira, Maria da Conceição Costa
Título en portugués
Desenvolvimento de detector de nêutrons utilizando cristal cintilador de CsI dopado com Li
Palabras clave en portugués
cristal cintilador
detector de nêutrons
lítio-6
MCNP
Resumen en portugués

A detecção da radiação e a medida de suas propriedades são requisitos para o desenvolvimento de todas as áreas da tecnologia nuclear e suas aplicações. Entre as suas aplicações, destacam-se: a pesquisa científica, a aplicação médica, a operação de reatores, a área de proteção radiológica e as aplicações industriais. A detecção dos nêutrons não é trivial, tendo em vista a falta de cargas elétricas dessas partículas e a peculiaridade de suas interações com a matéria. Outra dificuldade na detecção de nêutrons é que a radiação emitida pela fonte de nêutrons está sempre acompanhada de radiações de outras naturezas, o que dificulta a discriminação eletrônica dos impulsos gerados pelos nêutrons, dos gerados por outras radiações. Neste trabalho, foram estudados cristais baseados em CsI para aplicação como detectores de nêutrons usando como dopante o Li, avaliando a resposta de detecção de nêutrons em diferentes concentrações de dopantes (entre 10-1 M a 10-4 M). A reação do nêutron com o Li é dada como: n+6Li→3H(2,75 MeV) + 4He(2,05 MeV) com σ= 940 b. Foram feitos estudos com nêutrons provenientes da fonte de AmBe incidindo em blocos de parafina e avaliando a resposta dos detectores aos nêutrons termalizados incidentes no cristal. Um cristal puro de CsI foi usado como referência para avaliar o ganho de eficiência com o aumento da concentração de dopante na matriz CsI. O código MCNP foi usado para avaliar qual a melhor espessura do cristal cintilador para a obtenção de maior eficiência de detecção de nêutrons.

Título en inglés
Development of neutron detector using Li-doped CsI scintilator crystal
Palabras clave en inglés
lithium-6
MCNP
neutron detector
scintillator crystal
Resumen en inglés

The detection of radiation and the measurement of its properties are requirements for the development of all areas of nuclear technology and its applications. Among its applications, the following stand out: scientific research, medical application, reactor operation, radiation protection and industrial applications. The detection of neutrons is not trivial, considering the lack of electric charges of these particles and the peculiarity of their interactions with matter. Another difficulty in detecting neutrons is that the radiation emitted by the neutron source is always accompanied by radiation of other natures, which makes it difficult to electronically discriminate impulses generated by neutrons from those generated by other radiations. In this work, crystals based on CsI were studied for application as neutron detectors using Li as a dopant, evaluating the neutron detection response to different concentrations of dopants (from 10-1 M to 10-4 M). The reaction of the neutron with Li is given as: n+6Li→ 3H(2.75 MeV) + 4He(2.05 MeV) with σ= 940 b. Studies were carried out with neutrons from the AmBe source focusing on paraffin blocks and evaluating the response of the detectors to thermalized neutrons incident on the crystal. A pure CsI crystal was used as a reference to evaluate the efficiency gain with increasing dopant concentration in the CsI matrix. The MCNP code was used to evaluate the best thickness of the scintillator crystal to obtain the highest neutron detection efficiency.

 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-06-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.