• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.64.2021.tde-28092022-133619
Documento
Autor
Nombre completo
Valéria Lopes Ferreira Vianna
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2021
Director
Tribunal
Mattos, Wanessa Melchert (Presidente)
Batista, Alex Domingues
Silva, Sidnei Gonçalves da
Título en portugués
Extração e pré-concentração em ponto nuvem de sulfonamidas em amostras de leite bovino
Palabras clave en portugués
Leite
Ponto nuvem
Química verde
Sulfonamidas totais
Resumen en portugués
As sulfonamidas são antibióticos sintéticos utilizados para o tratamento de infecções bacterianas em humanos e animais e permitidas, de acordo com órgãos regulamentadores de resíduos de antibióticos em concentrações de até 100 g L-1 de sulfonamidas totais (sulfatiazol, sulfametazina e sulfadimetoxina). Dentre os procedimentos utilizados no preparo de amostra para determinação de sulfonamidas estão as extrações líquido-líquido convencional e em fase sólida que empregam elevados volumes de solventes orgânicos. Neste contexto, foi desenvolvido um procedimento limpo de extração e pré-concentração em ponto nuvem sem utilização de solventes orgânicos para determinação de sulfonamidas totais em leite bovino. O procedimento experimental foi otimizado, alíquotas de 2 mL da amostra límpida, 2 mL da solução reagente e 1 mL de Triton X-114 7% (m/v) foram adicionadas em tubo, aquecidas em banho maria a 40 °C por 10 minutos e centrifugadas por 20 minutos a 4000 rpm. A determinação por imagens digitais foi realizada diretamente no tubo, sem remoção da fase pobre em surfactante. Resposta linear foi observada entre 10 e 400 g L-1 de sulfonamidas totais, descrita pela equação Sinal analítico = 2,50 + 0,0514 C (g L-1) e R = 0,999. Limite de detecção e quantificação e o coeficiente de variação (n = 11) foram estimados em 10 g L-1 e 1,3%, respectivamente. As principais espécies concomitantes presentes na amostra não interferiram em concentrações usualmente encontradas. Estudos de adição e recuperação de sulfonamidas totais foram realizados em amostras de leite bovino UHT e pasteurizado obtendo porcentagens de recuperação entre 64 e 125%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de sulfonamidas totais em leite bovino e não emprega solventes orgânicos, atendendo aos preceitos da química analítica verde
Título en inglés
Extraction and preconcentration in a cloud point of sulfonamides in bovine milk
Palabras clave en inglés
Bovine milk
Cloud point
Green analytical chemistry
Sulfonamides
Resumen en inglés
Sulfonamides are synthetic antibiotics used to treat bacterial infections in humans and animals, which are allowed according to the regulatory agencies for antibiotic residues, up to 100 g L-1 of total sulfonamides (sulfathiazole, sulfamethazine and sulfadimethoxine). The procedures used in sample preparation for sulfonamides determination include conventional liquid-liquid and solid-phase extractions, which use high volumes of organic solvents. In this context, a clean extraction and pre-concentration procedure in a cloud point was developed without using organic solvents for determination of total sulfonamides in bovine milk. The experimental procedure was optimized, aliquots 2 mL of the clear sample, 2 mL of the reagent solution and 1 mL of Triton X-114 7% (w / v) were added in a tube, heated in a water bath at 40 °C for 10 minutes and centrifuged for 20 minutes at 4000 rpm. The determination by digital images was performed directly in the tube, without removing the poor surfactant phase. A linear response was observed between 10 and 400 g L-1 of total sulfonamides, described by the equation Analytical signal = 2.50 + 0.0514 C (g L-1) and R = 0.999. Detection and quantification limits and coefficient of variation (n = 11) were estimated at 10 g L-1 and 1.3%, respectively. The main concomitant species present in the sample did not interfere with concentrations usually found. Studies of spike and recovery of total sulfonamides were carried out on UHT and pasteurized bovine milk samples obtaining recovery percentages between 64 and 125%. The developed analytical procedure shows adequate sensitivity for the determination of total sulfonamides in bovine milk and does not use organic solvents, which meets the precepts of green analytical chemistry
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-10-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.