• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2023.tde-23102023-151543
Document
Author
Full name
Daniele Morais Dias
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2023
Supervisor
Committee
Galo, Rodrigo (President)
Júnior, Paulo Cézar Simamoto
Oliveira, Dhelfeson Willya Douglas de
Souza, Valéria Oliveira Pagnano de
Title in Portuguese
Análise da degradação química da superfície de titânio usinado modificada com quitosana
Keywords in Portuguese
Corrosão
Implante dentário
Quitosana
Titânio
Tratamento de superfície
Abstract in Portuguese
A fim de promover melhorias, diversos manejos podem ser realizados para modificar a superfície de implantes dentários. O presente trabalho avaliou a deposição de camadas de quitosana sobre a superfície de titânio usinado, por meio da técnica camada por camada (layer-by-layer ou LbL). Esta metodologia permitiu a formação de um filme de proteção a partir de multicamadas de polieletrólitos (PEMs), utilizando ® quitosana de baixo peso molecular Sigma®. O comportamento da corrosão do titânio usinado foi analisado sem revestimento, em 08 e 12 bicamadas, utilizando solução de soro fisiológico com auxílio de um eletrodo de calomelano (SCE). As amostras foram obtidas através de compostos de titânio usinado, em formato cilíndrico, nas dimensões de 13,0 mm de diâmetro e 2,0 mm de espessura e foram polidas com lixas abrasivas até a granulação de 1200 na presença de água. Os testes eletroquímicos foram realizados através do potencial em circuito aberto (Ecorr) por 1 hora e polarização anódica (icorr) nos valores de potencial variando entre -500 milivolts (mV) e 2000 mV, com scan rate de 2 mVs-1 , com n=5. Análises complementares foram realizadas na superfície do Ticp por meio do microscópio eletrônico de varredura (MEV), microscopia de confocal e espectroscopia de difração de RX (XRD), onde foi possível identificar as alterações que ocorreram na superfície do titânio. A respeito do crescimento dos filmes, um microscópio de força atômica (AFM) foi utilizado. Os dados foram analisados pelos testes de homogeneidade e, como a amostra apresentou distribuição normal, os testes paramétricos foram utilizados (ANOVA). Através do presente estudo pode-se concluir que a deposição de 08 camadas de titânio é mais interessante quando comparada a 12 camadas.
Title in English
Surface chemical degradation analysis titanium with chitosan modification
Keywords in English
Chitosan
Corrosion
Dental implant
Surface treatment
Titanium
Abstract in English
In order to promote improvements, several managements can be performed to modify the surface of dental implants. The present work evaluated the deposition of layers of chitosan on the surface of machined titanium, using the layer-by-layer technique (layer-by-layer or LbL). This methodology allowed the formation of a protective film from polyelectrolyte multilayers (PEMs), using Sigma® low molecular weight chitosan. The corrosion behavior of machined titanium was analyzed without coating, in 08 and 12 bilayers, using saline solution with the aid of a calomel electrode (SCE). The samples were obtained from machined titanium compounds, in a cylindrical shape, with dimensions of 13.0 mm in diameter and 2.0 mm in thickness, and were polished with abrasive sandpaper to a grain of 1200 in the presence of water. Electrochemical tests were performed using open circuit potential (Ecorr) for 1 hour and anodic polarization (icorr) at potential values ranging from -500 millivolts (mV) to 2000 mV, with a scan rate of 2 mVs-1, with n =5. Complementary analyzes were carried out on the Ticp surface using scanning electron microscopy (SEM), confocal microscopy and X-ray diffraction spectroscopy (XRD), where it was possible to identify the alterations that occurred on the titanium surface. Regarding the growth of the films, an atomic force microscope (AFM) was used. Data were analyzed using homogeneity tests and, as the sample had normal distribution, parametric tests were used (ANOVA). Through the present study it can be concluded that the deposition of 08 layers of titanium is more interesting when compared to 12 layers.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2023-11-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.