Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2023.tde-05022024-132816
Documento
Autor
Nombre completo
Helena Taeko Tanaka Oyama
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2023
Director
Tribunal
Torres, Marcelo Luis Abramides (Presidente)
Fechine, Guilhermino José Macêdo
Malmonge, Sonia Maria
Rubio, Mario Ricardo Gongora
Título en portugués
Modificações das superfícies de poliuretanos para aumentar a hemocompatibilidade de dispositivos cardiovasculares
Palabras clave en portugués
Fotoenxertia
Hemocompatibilidade
Heparina
Óxido de grafeno
Óxido de grafeno reduzido
Tratamento de superfície
Resumen en portugués
A hemocompatibilidade representa um dos principais requisitos dos materiais utilizados em dispositivos médicos que entram em contato direto com o sangue. O objetivo desse trabalho foi desenvolver e avaliar estratégias de tratamentos de superfície para aumentar a hemocompatibilidade do Poliéter Poliuretano Segmentado (PU) utilizado na confecção de dispositivos cardiovasculares. Duas estratégias foram propostas e avaliadas: a) a funcionalização da heparina na superfície do polímero pelo processo de fotoenxertia e b) a incorporação de nanocargas, de óxido de grafeno (GO) e óxido de grafeno reduzido (rGO) com a heparina, na massa polimérica. Os tratamentos foram avaliados de acordo com ensaios definidos nas normas internacionais que incluem as caracterizações físico-químicas dos materiais e avaliações biológicas. As caracterizações termogravimétricas e por espectroscopias Raman mostraram a redução do GO com a heparina. As análises por FTIR também confirmaram a redução do GO e a funcionalização do heparinato de benzalcônio na superfície do PU. Os ensaios mecânicos de tração mostraram uma variação da resistência à tração entre as membranas de PU e as membranas dos nanocompósitos. As membranas de PUrGO tiveram maior tensão para uma mesma deformação de 500%. Esta membrana, na concentração de 0,2% de rGO, em 100% de deformação, apresentou um valor de módulo de Young de 16,41% maior que o PU puro. Houve redução do ângulo de contato das membranas as membranas de PU tratadas por fotoenxertia de 88,5o para 65,1o, tornando-as mais hidrofílicas. Os nanocompósitos de PU com rGO apresentaram aumento no ângulo de contato de 88,5o para 97,1o sugerindo aumento de hidrofobicidade. Os ensaios biológicos in vitro sugerem menor adesão de plaquetas em superfícies mais hidrofílicas de PUHepB do que em superfícies hidrofóbicas. A atividade hemolítica na superfície de PUrGO se mostrou menor nas superfícies mais hidrofóbicas do que nas membranas hidrofílicas. Os resultados dos ensaios de citotoxicidade sugerem que as membranas de PU e as membranas tratadas apresentaram adesão e proliferação celular o que indica boa biocompatibilidade
Título en inglés
Modifications of polyurethane surfaces to increase hemocompatibility of cardiovascular devices
Palabras clave en inglés
Graphene oxide
Hemocompatibility
Heparin
Photografting
Reduced graphene oxide
Surface treatment
Resumen en inglés
Hemocompatibility represents one of the main requirements of materials used in medical devices that come into direct contact with blood. The purpose of this work was to develop and evaluate surface treatment strategies to increase the hemocompatibility of Segmented Polyether Polyurethane (PU) used in the manufacture of cardiovascular devices. Two strategies were proposed and evaluated: a) the functionalization of heparin on the polymer surface by the photografting process and b) the incorporation of nanofillers, graphene oxide (GO) and reduced graphene oxide (rGO) with heparin, in the polymer mass . The treatments were evaluated according to tests defined by international norms, which include the physical-chemical characterization of the materials and biological evaluations. Thermogravimetric and Raman characterizations spectroscopy showed the reduction of GO with heparin. FTIR analyses showed the reduction of GO and the functionalization of benzalkonium heparinate on the PU surface. The mechanical tensile tests showed a variation in tensile strength between the PU membranes and the nanocomposite membranes. The PUrGO membranes had a higher tension for the same 500% deformation. This membrane, at a concentration of 0.2% rGO, at 100% deformation, presented a Young's modulus value of 16.41% higher than pure PU. There was a reduction in the contact angle of the PU membranes treated by photografting from 88.5o to 65.1o, making them more hydrophilic. The PU nanocomposites with rGO showed an increase in the contact angle from 88.5o to 97.1o, suggesting increased hydrophobicity. Biological assays, in vitro, suggest less platelet adhesion to more hydrophilic PUHepB surfaces than to hydrophobic surfaces. The hemolytic activity on the PUrGO surface was lower on the more hydrophobic surfaces than the hydrophilic membranes. The results of the cytotoxicity assays suggest that the PU membranes and the treated membranes showed cell adhesion and proliferation, which indicates good biocompatibility
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-02-19