• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.43.2022.tde-08032022-102912
Documento
Autor
Nombre completo
Lucas de Arruda Serra Filho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2022
Director
Tribunal
Bregant, Marco (Presidente)
Genezini, Frederico Antonio
Júnior, Herman Pessoa Lima
Título en portugués
Detector de nêutrons térmicos baseado em GEM com deposição de 10B4C sobre cátodo de alumínio
Palabras clave en portugués
alternativas ao 3He
detecção de nêutrons
detectores gasosos microestruturados
Gas Electron Multiplier
Resumen en portugués
Desde sua descoberta em 1932, nêutrons tiveram um papel essencial no entendimento da física nuclear. Como não interagem por meio de forças elétricas, eles constituem partículas desafiadoras para detecção. Desenvolvimentos cruciais como os realizados por Shull e Brockhouse permitiram usar nêutrons para, além da geração de energia, o estudo de propriedades estáticas e dinâmicas da matéria. Com a escassez de 3He, o isótopo mais utilizado para detecção de nêutrons, a comunidade científica iniciou a busca por métodos viáveis de detecção de nêutrons, utilizando isótopos alternativos como 157Gd, 10B, e 6Li, que também apresentam alta seção de choque de captura para nêutrons térmicos. Paralelamente, o interesse em ciência de nêutrons tem crescido devido aos diversos avanços nas técnicas de espalhamento, amplamente utilizadas em várias áreas como Química, Física, Biologia e Engenharia. Tais avanços dependem do desenvolvimento de detectores, que também cresceu nos últimos anos, juntamente com a capacidade de se obter feixes de nêutrons monocromáticos tanto em pequenas como grandes instalações. Para aplicações que requerem grandes áreas e volumes de detecção, os detectores a gás ainda são uma escolha importante. A nova geração de detectores gasosos, os detectores gasosos microestruturados (MPGDs) como o multiplicador gasoso de elétrons (GEM), introduziu novas características, apresentando melhor resolução espacial e de energia, capacidade de operação sob altas taxas de radiação, melhor performance ao longo do tempo e preço competitivo, os tornando amplamente utilizados em vários experimentos. Este trabalho consistiu em projetar, construir e caracterizar um detector de nêutrons a gás, sensível à posição, que utiliza GEMs. Utilizamos  10B4C como conversor de nêutrons térmicos, depositado sobre o cátodo de alumínio do detector. O protótipo apresentou resolução espacial de pelo menos 3 mm e 2.66(30) % de eficiência de detecção, como calculado pelos modelos teóricos adotados neste trabalho. Também se demonstrou estável para longas aquisições sendo uma alternativa versátil para várias aplicações futuras.
Título en inglés
GEM-based thermal neutron detector with  10B4C deposition on aluminum cathode
Palabras clave en inglés
3He alternative
Gas Electron Multiplier
micropattern gaseous detectors
neutron detectors
Resumen en inglés
Since its discovery in 1932, neutrons have had a central role in the understanding of nuclear physics. As they do not interact via electric forces, they constitute a challenging particle to detect. Crucial developments such as the ones by Shull and Brockhouse allowed using neutrons beyond energy generation to study matter's static and dynamic properties. With the shortage of 3He, the most common isotope used in neutron detection, the scientific community started to pursue viable neutron detection methods using alternative isotopes such as 157Gd, 10B, and 6Li, which also have high neutron capture cross-section. At the same time, the interest in neutron science increased due to the several advances in scattering techniques, widely used in many areas such as chemistry, physics, biology, medicine, and engineering research. These advances depend on detector development which has grown in the last years, together with the ability to obtain bright monochromatic neutron sources, whether in large or small facilities. For applications that demand high volumes or areas, gaseous detectors are still an important choice. The new generation of the gaseous detectors, the micropattern gaseous detectors (MPGDs), such as the gas electron multiplier (GEM), introduced new features: presenting better spatial and energy resolution, capacity to operate at higher rates, better performance stability over time, and competitive cost making them widely used nowadays in several experiments. This work consisted of projecting, building, and characterizing a position-sensitive gaseous neutron detector prototype made of GEMs. We used 10B4C as a thermal neutron converter deposited over the aluminum cathode of the detector. It presented at least 3 mm spatial resolution and 2.66(30) % neutron detection efficiency, agreeing with the values evaluated from the theory used in this work. It is also stable for long runs and consists of a versatile alternative for several further applications.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-03-17
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.