• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2024.tde-18042024-091104
Document
Auteur
Nom complet
Patricia Akemi Sekini Guenkawa
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2024
Directeur
Jury
Furuie, Sérgio Shiguemi (Président)
Matsumoto, Mônica Mitiko Soares
Sims, John Andrew
Titre en portugais
Detecção e localização de cavitação via inteligência artificial.
Mots-clés en portugais
AlexNet
Bioengenharia
Detecção de cavitação
Inteligência artificial
Sonotrombólise
Resumé en portugais
O infarto do miocárdio é uma das principais causas de morbidade e mortalidade em todo o mundo. Dentre os possíveis tratamentos para obstrução do fluxo sanguíneo, uma técnica emergente é denominada sonotrombólise. Para alcançar resultados satisfatórios, o evento aliado à técnica (cavitação de microbolhas) precisa ser controlado para evitar danos ao paciente. Diante disso, este estudo teve como objetivo detectar e classificar o fenômeno durante a terapia de sonotrombólise por meio de inteligência artificial, onde a região de interesse é o coração. Os sinais foram gerados utilizando a ferramenta k-Wave disponível para Matlab, onde podem ser definidas características do meio acústico, incluindo não linearidades, atenuações e a topologia da matriz de transdutres. Após a simulação desses sinais, foi proposto um método classificador automático e descomplicado, baseado na ferramenta Transformada Wavelet Contínua e abordagem de Rede Neural Convolucional (CNN). O método utilizou uma CNN pré-treinada, chamada AlexNet, operando uma base de dados de 2.800 sinais para treinamento (70%), teste (15%) e validação (15%). As métricas de avaliação incluíram tanto a detecção em banda larga e estreita, o nível de ruído aplicado e o tamanho da base de dados. Para o caso dos receptores de banda estreita, os resultados do estudo indicaram que a técnica alcançou valores em torno de 95,7% e 96,0% para acurácia e precisão, respectivamente. O considerável grau de acurácia demonstrou que o uso de inteligência artificial pode ser uma abordagem para explorar a detecção de cavitação para terapias que fazem uso de ultrassom.
Titre en anglais
Detection and location of cavitation through artificial intelligence.
Mots-clés en anglais
AlexNet
Artificial intelligence
Cavitation detection
Sonothrombolysis
Resumé en anglais
Myocardial infarction is one of the main causes of morbidity and mortality worldwide. Among the possible treatments for blood flow obstruction is an emerging technique named sonothrombolysis. To reach satisfactory results, the event allied to the technique (cavitation of microbubbles) needs to be controlled to avoid harm to the patient. Given that, this study aimed to detect and classify the phenomenon during sonothrombolysis therapy through artificial intelligence, where the region of interest is the heart. The signals were generated using the k-Wave toolbox available for MATLAB, where features of the acoustic medium can be set, including non-linearities, attenuations, and the matrix array topology. After the simulation of those signals, an automatic and uncomplicated classifier method was proposed, based on the Continuous Wavelet Transform tool and Convolutional Neural Network (CNN) approach. The method made use of a pre-trained CNN, called AlexNet, operating a database of 2,800 synthetic waves for training (70%), testing (15%), and validation (15%). The evaluation included both the detection using broad and narrowband detectors, the noise level applied, and the database size. For the case of narrowband receivers, the results of the study indicated that the technique achieved state-of-the-art values of around 95.7%, and 96.0% for accuracy and precision, respectively. The considerable degree of accuracy demonstrated that using artificial intelligence could be an approach to explore the detection of cavitation for therapies using ultrasound signals.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-04-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.