Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2012.tde-24102023-151323
Documento
Autor
Nombre completo
Daniel Soliani de Castro
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Coelho, Tarcisio Antonio Hess (Presidente)
Cestari, Idágene Aparecida
Souza, Gilberto Francisco Martha de
Título en portugués
Dispositivo auxiliar de cirurgia para correção da diástase da aponeurose dos músculos retos abdominais.
Palabras clave en portugués
Administração de risco
Bioengenharia
Cirurgia
Engenharia de requisitos
Instrumentos de precisão
Mecanismos
Resumen en portugués
Durante a gravidez, uma série de fatores (obesidade, multiparidade, gestações múltiplas, entre outros) pode impor à região abdominal uma pressão excessiva que faça com que seja excedido o limite elástico da aponeurose dos músculos abdominais. Essa sobre-distensão é chamada de diástase da aponeurose. Sua permanência pode gerar problemas funcionais (dor lombar, possível herniação, cálculo renal) e estéticos (globosidade da região). A correção da diástase é feita após o parto por meio de plicaturas (tracionamento através de costura) na aponeurose. Quando a distensão ocorre no segmento meso-hipogástrico (entre cicatriz umbilical e púbis), é corrigida juntamente com a cesariana. Já no segmento mesoepigástrico (entre cicatriz umbilical e apêndice xifoide), é necessário aumento da incisão de Pfannenstiel (cesariana) para que seja realizada, o que gera consequências estéticas evidentes e indesejadas. Tendo como foco a correção da diástase no segmento mesoepigástrico, foi desenvolvido o projeto conceitual de um dispositivo mecatrônico que auxilie a correção desse problema sem a necessidade de aumento da incisão de Pfannenstiel. A partir de uma agulha de crochê tunisiano, o dispositivo realiza uma sutura contínua com inversão de bordas para correção da diástase o que permite reduzir o impacto estético adicional a uma ou mais incisões de três milímetros na região lateral abdominal. O mecanismo possui automatizações para auxiliar o cirurgião na execução da plicatura. O desenvolvimento foi feito de acordo com as normas da Anvisa para equipamentos eletromédicos. Foi efetuado o gerenciamento de riscos (de acordo com a Anvisa, ISO e PMI) e a engenharia de requisitos em domínios disjuntos do dispositivo. O resultado do desenvolvimento se mostrou eficiente, adaptável e seguro.
Título en inglés
Auxiliary device for the rectus abdominis muscles diastasis correction surgery.
Palabras clave en inglés
Aponeurosis
Biomedical engineering
Mechanism
Precision mechanics
Requirement engineering
Risk management
Surgery
Resumen en inglés
During pregnancy, several factors, such as obesity, multiparity and multiple gestations, lead to a pressure increase over the abdominal walls. As a consequence, this condition may cause the muscles aponeurosis to exceed its elastic limit. This excessive extension generates the softening of the abdominal walls, known as aponeurosis diastasis. Due to this reduction of pressure, one may experience functional (lumbar pain, hernia, renal calculus) and aesthetic (globosity region) issues. The diastasis correction is usually achieved by aponeurosis plications (traction through sewing). When the meso-hypogastrium region (between the umbilical scar and pubis) is affected, the correction is performed at the same time as the cesarean procedure. On the other hand, if it occurs in the mesoepigastric region (between the umbilical scar and xiphoid appendix), it is required an increase of the Pfannenstiel incision, resulting in a much more aggressive procedure with aesthetic consequences. Focusing on the correction of the mesoepigastric region diastasis, this work deals with the conceptual design of a device capable to assist the surgeon to correct this problem, in a minimally invasive procedure, without the need to increase the Pfannestiel incision. From a tunisian crochet needle, the device does a continuous suture, performing one or more 3-mm incisions in the lateral abdominal wall, which are the only aesthetical impacts of the procedure. During the device development, the approaches of the Risk Management (ISO, PMI, Anvisa) and the Requirements Engineering of disjoint domains have been applied. In addition, the characteristics of the conceived device follow the regulations of the National Health Surveillance Agency (Anvisa). Finally, the designed device demonstrates a promising potential to be efficient, adaptable and safe.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-10-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.