• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.3.2023.tde-21092023-092123
Document
Author
Full name
Rodolfo Varraschim Rocha
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2023
Supervisor
Committee
Monaro, Renato Machado (President)
Chabu, Ivan Eduardo
Coury, Denis Vinicius
Lima, Francisco Kleber de Araújo
Silva, Kleber Melo e
Title in Portuguese
Análise de faltas internas em geradores síncronos de velocidade variável conectados a conversores de três níveis.
Keywords in Portuguese
Faltas entre espiras
Faltas internas
Gerador síncrono
Proteção elétrica
Velocidade variável
Abstract in Portuguese
Este trabalho traz uma análise detalhada dos efeitos de faltas entre espiras, sem envolvimento com Terra, no enrolamento de estator dos geradores síncronos de polos salientes eletricamente excitados conectados a inversores bidirecionais do tipo Neutral Point Clamped de três níveis. Adicionalmente, é proposto um algoritmo para detecção dessas faltas usando as medidas de correntes elétricas tipicamente adquiridas para fins de controle do gerador para evitar a necessidade de instalação de sensores adicionais. As faltas entre as espiras do estator causam mudanças específicas no conteúdo harmônico das correntes de linha e campo do gerador, as quais são filtradas e usadas para detecção da ocorrência das faltas. A mudança nas características da corrente do neutro do inversor de três níveis conectado ao gerador também é avaliada para detecção das faltas. Para detectar as componentes harmônicas selecionadas em diferentes velocidades, são usados filtros dinâmicos baseados nas transformadas / e de Fourier, que empregam a medida de posição do rotor para se adaptar às mudanças de frequências das componentes sob diferentes velocidades. Então, os lugares geométricos das componentes são propostos como parâmetro para distinguir entre condições saudáveis e defeituosas. Dados de simulação e experimentais são considerados para testar a sensibilidade, seletividade e tempo de detecção da técnica proposta para diferentes casos de faltas. A avaliação para um gerador de 4, 5 MW também é apresentada considerando simulações computacionais.
Title in English
Internal faults analysis in variable speed synchronous generators connected to three-level converters.
Keywords in English
Internal faults
Protection
Three-level Inverter
Turn faults
Variable-speed
Wound rotor synchronous generator,Salient pole
Abstract in English
This work presents a detailed analysis of the effects of turn faults, without ground contact, on the stator winding of electrically excited salient pole synchronous generators connected to three-level Neutral Point Clamped bidirectional inverters. Moreover, an algorithm to detect these faults using measurements of electrical currents typically acquired for control purposes is proposed, in order to avoid the need to install additional sensors. Faults between stator turns cause specific changes in the harmonic content of the generator line and field currents, which are filtered and used for fault detection. The changes in the characteristics of the neutral current of the three-level inverter connected to the generator is also evaluated for fault detection. To detect selected harmonic components at different speeds, dynamic filters based on abc/dq and Fourier transforms are used, which employ the rotor position measurement to adapt to frequency changes of the components under different speeds. Then, the geometric loci are proposed as a parameter to distinguish between healthy and faulty conditions. Simulation and experimental dataare used to test the sensitivity, selectivity and detection time of the proposed technique for different fault cases. The evaluation for a 4.5 MW generator is also performed through computational simulations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2023-09-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.