Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2022.tde-27052022-091056
Documento
Autor
Nombre completo
Kaique Figueiredo Sanches
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2022
Director
Tribunal
Carreno, Marcelo Nelson Paez (Presidente)
Bartoli, Julio Roberto
Fontes, Marcelo Bariatto Andrade
Título en portugués
Desenvolvimento de microssensores MEMS, visando implantação in vivo para o estudo da fadiga muscular.
Palabras clave en portugués
Microagulhas
Microsensores
Microsensores eletroquímicos
Sensores
Sistemas microeletromecânicos
Resumen en portugués
Na presente pesquisa, foram projetadas e fabricadas matrizes de microeletrodos através das técnicas da microeletrônica e MEMS. Sobre o silício microusinado, com formato de microagulhas (espessura de 100 m), há 3 pares de eletrodos, sendo um eletrodo de referência (Ag) e um eletrodo de trabalho (Au), que podem ser utilizadas para estudos in vivo. Os eletrodos de ouro foram testados, através da voltametria cíclica, em solução de ferricianeto de potássio e apresentaram: (i) ocorrência do processo faradico nas características E1/2 ~ 0,25 V da redução de ferricianeto; (ii) baixa histerese; e (iii) estabilização da corrente limite. Os microelétrodos, também apresentaram boa resposta em solução de ácido sulfúrico, exibindo os picos de característica de oxidação (Ep = 1,5 V) e redução (Ep = 0,9 V) das superfícies de ouro. Foi realizado o processo amperométrico aplicando um potencial E = -0.8V por 600 s, em seguida inicia-se 50 ciclos na voltametria cíclica variando a tensão com passo de 100 mV/s em solução [Ir(COO)2(OH)4]2- pH (10,5), para a deposição do filme de IrOx, que deixa o microelétrodo de Au sensível ao pH. Utilizando solução 0,1 mol/L de PBS (pH 7.0) e variação v = 100 mV/s, antes e depois da deposição do filme de IrOx, foi possível verificar que os dispositivos são sensíveis a variação de pH. Foram realizadas medições de OCP em 0,1 mol/L de PBS com diferentes valores de pH, com base nos valores de tensão foi possível traçar uma reta que pode ter inclinações variando de -59 a -90 mV por unidade de pH a temperatura ambiente.
Título en inglés
Development of mems microsensors, aiming in vivo implantation for the study of muscular fatigue.
Palabras clave en inglés
Electrochemical sensor
Implantable electrodes
MEMS
Microelectrodes
Microneedles
Resumen en inglés
In the present study, microelectrode arrays were designed and manufactured using microelectronics and MEMS techniques. On the micromachined silicon, with microneedle format (thickness of 100 m), there are 3 pairs of electrodes, being a reference electrode (Ag) and a working electrode (Au), which can be used for in vivo studies. The gold electrodes were tested, through cyclic voltammetry, in potassium ferricyanide solution and showed: (i) occurrence of the faradic process in the characteristics E1/2 ~ 0.25 V of the ferricyanide reduction; (ii) low hysteresis; and (iii) stabilization of the limit current. The microelectrodes also showed good response in sulfuric acid solution, showing the characteristic oxidation (Ep = 1.5 V) and reduction (Ep = 0.9 V) peaks of the gold surfaces. The amperometric process was carried out by applying a potential E = -0.8V for 600 s, then 50 cycles of cyclic voltammetry were started, varying the voltage with a step of 100 mV/s in solution [Ir(COO)2(OH)4] 2- pH (10.5), for the deposition of the IrOx film, complaining about the pH-sensitive Au microelectrode. Using 0.1 mol/L PBS solution (pH 7.0) and variation v = 100 mV/s, before and after deposition of the IrOx film, it was possible to verify that the devices are sensitive to pH variation. OCP measurements were performed in 0.1 mol/L of PBS with different pH values, based on the voltage values it was possible to draw a straight line that can have slopes ranging from -59 to -90 mV per pH unit at room temperature.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-05-27
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.