• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.3.2023.tde-26072023-071556
Document
Auteur
Nom complet
Amir Hossein Omidvar
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2023
Directeur
Jury
Rehder, Gustavo Pamplona (Président)
Onmori, Roberto Koji
Ponchet, André da Fontoura
Schianti, Juliana de Novais
Silva, Davinson Mariano da
Titre en portugais
Projeto, fabricação e aplicação de biossensores de glicose não enzimáticos.
Mots-clés en portugais
Biosensores
Filmes finos
Glicose
Polímeros de impressão
Sensores de micro-ondas
Resumé en portugais
O diabetes é uma das quatro principais doenças não transmissíveis e se tornou uma das doenças que mais crescem no mundo. Será a sétima principal causa de morte em todo o mundo até 2030. A Federação Internacional de Diabetes (IDF) divulgou um novo relatório que demonstra que a população global com diabetes atingiu 537 milhões, aumentando 16% desde sua estimativa anterior em 2019. Infelizmente, não há cura conhecida para esta condição crônica de saúde; a única alternativa para prevenir complicações para pacientes com diabetes é monitorar constantemente seus níveis de glicose no sangue. Além disso, o intervalo seguro para os níveis de glicose no sangue é muito estreito (entre 80-120 mg/dl). Portanto, o método de detecção deve ser capaz de detectar uma ligeira mudança na concentração nesta faixa. Para medir o nível de glicose, os biossensores são muito práticos. Um biossensor é um transdutor capaz de converter uma resposta biológica em um sinal mensurável. É apresentado um novo polímero de impressão molecular biossensorial com microfluido de micro-ondas sensível e de baixo custo. O dispositivo sensor é baseado em ressonadores de stub duplos para caracterizar soluções de glicose na água. A ponta de um dos stubs é revestida com MIP para aumentar a seletividade do sensor e, portanto, a sensibilidade em comparação com o polímero não revestido ou não impresso. O sensor foi fabricado em substrato FR4 para fins de baixo custo. Na presença do MIP, observou-se que o sensor carregado com uma solução de glicose variando de 50 mg/dL a 400 mg/dL experimentou uma mudança de frequência de absorção de 73 MHz quando as soluções fluem em um canal microfluídico passando pela área de detecção, enquanto o sensor Descobriu-se que o LLD do sensor era de 2,4 ng/dL. Os resultados experimentais mostraram uma alta sensibilidade de 1,3 MHz /(mg/dL) em termos de frequência de absorção.
Titre en anglais
Non enzymatic glucose biosensor design, fabrication, and application.
Mots-clés en anglais
Aluminum nitride
Biosensor
Glucose
Microwave resonators
Molecular imprinted polymer
Thin film
Resumé en anglais
Diabetes is one of the four main noncommunicable diseases and has become one of the fastestgrowing diseases in the world. It will be the seventh leading cause of death worldwide by 2030. The International Diabetes Federation (IDF) has released a new report that demonstrates the global population with diabetes has reached 537 million, increasing 16% since their previous estimation in 2019. Unfortunately, there is no known cure for this chronic health condition; the only alternative to prevent complications for diabetes patients is constantly monitoring their blood glucose levels. Also, the safe range for blood glucose levels is very narrow (between 80-120 mg/dl). Therefore, the sensing method should be able to detect a slight change in concentration in this range. In order to measure the glucose level, biosensors are very practical. A biosensor is transducer capable of converting a biological response into a measurable signal. A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer is presented. The sensing device is based on dual stub resonators to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the selectivity of the sensor and hence the sensitivity compared to the uncoated or non-imprinted polymer one. The sensor was fabricated on an FR4 substrate for low-cost purposes. In the presence of the MIP, the sensor load-ed with a glucose solution ranging from 50 mg/dL to 400 mg/dL was observed to experience an absorption frequency shift of 73 MHz when the solutions flow in a microfluidic channel passing sensing area, while the Lower Limit of Detection (LLD) of the sensor was discovered to be 2.4 ng/dL. The experimental results showed a high sensitivity of 1.3 MHz /(mg/dL) in terms of absorption frequency.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-07-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.