Master's Dissertation
DOI
https://doi.org/10.11606/D.3.1994.tde-29112023-152105
Document
Author
Full name
Helio Valentini Junior
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1994
Supervisor
Committee
Loureiro, Luiz Valcov (President)
Franca, Fernando de Almeida
Zerbine, Euryale Jorge Godoy de Jesus
Title in Portuguese
Identificacao dos regimes, em escoamento bifasico gas-liquido, atraves do uso de transdutores de impedancia.
Keywords in Portuguese
Escoamento bifásico
Abstract in Portuguese
Este trabalho consistiu no emprego de transdutores de impedância na medida de fração de vazio e na identificação dos regimes de escoamento, ambos parâmetros de fundamental importância em escoamento bifásico gás-liquido. Foram construídos três transdutores de impedância, os quais foram montados numa seção vertical. A seção de testes era transparente, para permitir a visualização do escoamento. Escoamento bifásico era produzido injetando-se ar e agua na seção de testes. Os transdutores de impedância foram calibrados para uma faixa de fração de vazio de 0% a 80%, aproximadamente. Nesta faixa, os transdutores se mostraram instrumentos bastante lineares. A calibração dos transdutores foi feita pelo método gravimétrico. A adequação deste método foi avaliada teoricamente. Foram estabelecidos critérios para identificação dos regimes de escoamento, os quais estão baseados na função densidade de probabilidade da parte flutuante do sinal de um transdutor de impedância.
Title in English
Untitled in english
Keywords in English
Two-phasic flow
Abstract in English
This work consisted of the employment of impedance transducers on the measurement of void fraction ando n the identification of flow regimes. These parameters are of fundamental importance in two-phase gas-liquid flow. Three impedance transducers were built, which were mounted in a vertical test section. Teh test section was transparente in order to enable flow visualization, Two-phase flow was produced injecting air and water in the test section. The impedance transducers were calibrated for a void fraction range from ) to 80 % approximately. In this range the transducers showed a linear response. The transducers calibration was made through the gravimetric method. The suitability of the method was evaluated theoretically. Some criteria for the identification of the flow regimes were established. These are based on the probability density function of the fluctuating part of an impedance transducers signal.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.