Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2008.tde-08052024-161915
Documento
Autor
Nombre completo
Fausto Enokibara
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2008
Director
Tribunal
Canale, Lauralice de Campos Franceschini (Presidente)
Casteletti, Luiz Carlos
Motheo, Artur de Jesus
Título en portugués
Caracterização superficial e análise da resistência à corrosão de ligas de titânio em meios fluoretados
Palabras clave en portugués
corrosão
fluoreto
ligas de titânio
saliva artificial
titânio
Resumen en portugués
O titânio e suas ligas são empregados em odontologia por apresentarem propriedades como excelente resistência à corrosão e biocompatibilidade. Embora a liga de titânio Ti-6Al-4V seja uma das mais utilizadas, estudos recentes contestam a biocompatibilidade do alumínio e do vanádio. Esse fato tem motivado a busca por outras ligas de titânio, como as ligas do sistema Ti-Mo. Este trabalho avalia a resistência à corrosão da liga Ti-10Mo, comparativamente à liga Ti-6Al-4V, em diferentes meios fisiológicos. Estuda a influência exercida por um meio similar à saliva, além de avaliar o comportamento devido à presença de íons fluoreto e de um meio ácido. A relação entre resistência à corrosão e porcentagem de molibdênio das ligas do sistema Ti-Mo foi analisada através da comparação entre as ligas Ti-10Mo e Ti-7,5Mo. Foi verificado também o motivo pelo qual o aço inoxidável austenítico AISI 316L, utilizado em implantes ortopédicos, não possui aplicação em implantes odontológicos. O comportamento dos óxidos formados nas ligas Ti-6Al-4V e Ti-10Mo nos eletrólitos estudados foi avaliado através das técnicas de EDX e XPS. Os resultados mostram que a resistência à corrosão das ligas de titânio estudadas tornam possível sua utilização em implantes dentários desde que obedeçam requisitos como a biocompatibilidade, mas a influência dos íons fluoreto e baixos valores de pH tornam-nas suscetíveis à corrosão. A avaliação superficial mostrou que existe uma variedade de óxidos para as ligas Ti-6Al-4V e Ti-10Mo antes da polarização. Após a polarização, a liga Ti-6Al-4V apresenta somente o óxido TiO2 enquanto que a liga Ti-10Mo apresenta uma variedade de óxidos de molibdênio permitindo uma melhor resistência à corrosão nesta condição
Título en inglés
Caracterização superficial e análise da resistência à corrosão de ligas de titânio em meios fluoretados
Palabras clave en inglés
artificial saliva
corrosion
fluoride
pH
titanium
titanium alloys
Resumen en inglés
Titanium and its alloys are used in dentistry because of their excellent properties as corrosion resistance and biocompatibility. Although the Ti-6Al-4V alloy has been widely used, recent works have demonstrated deleterious effects of aluminum and vanadium. This fact has been motivated the demand for other titanium alloys as TiMo system. The aim of this study is to evaluate the corrosion resistance of Ti-10Mo comparing with Ti-6Al-4V performance in different body fluid environment. Study the influence of a salivary environment and the corrosion behavior in the presence of fluoride contents and different pH values. The relation between corrosion resistance and molybdenium contents in TiMo alloys was analyzed through a comparative study between Ti-10Mo and Ti-7,5Mo. It was verified the reason for the austenitic stainless steel AISI 316L widely used in orthopedic implants has not been recommended in dentistry. X-Ray electron spectroscopy (XPS) and scanning electron microscopy (SEM) were undertaken to study the elemental composition and structure of the surface films after and before the potencyodinamic polarization in acid-fluoride salivary solution. The results showed that the corrosion resistance of both alloys turns possible their use in dentistry since the biocompatibility had been proved, but the fluoride influence and low values of pH turn the alloys susceptible to corrosion. The XPS tests before the polarization showed a variety of titanium oxides for both alloys and only the presence of TiO2 after the polarization, but for the Ti-10Mo the XPS showed a variety of molybdenum oxides after polarization giving the better corrosion resistance in the acid-fluoride salivary solution than Ti-6Al-4V
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-05-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.