Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2020.tde-02052023-151717
Document
Auteur
Nom complet
Lisiane Pereira Prado
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2020
Directeur
Jury
Carrazedo, Ricardo (Président)
Araujo, Daniel de Lima
Barbosa, Mônica Pinto
Figueiredo, Antonio Domingues de
Haach, Vladimir Guilherme
Titre en portugais
Estudo da interface do concreto pré-moldado e concreto de altíssimo desempenho reforçado com fibras
Mots-clés en portugais
CAR
Interface
Modelo numérico
Rugosidade
UHPC
Resumé en portugais
O concreto de alta resistência (CAR) tem sido muito utilizado na confecção de estruturas de concreto pré-moldado. Uma das dificuldades encontradas nesse sistema construtivo consiste em estabelecer uma ligação monolítica entre os elementos. A solução frequente consiste no preenchimento com moldagem no local utilizando o CAR e um arranjo de armadura específico. Atualmente, o concreto de altíssimo desempenho reforçado com fibras (UHPC – sigla em inglês), com propriedades mecânicas elevadas (resistência à tração e compressão) e boa durabilidade, surge como opção de preenchimento da região da ligação destes elementos. Neste caso, a eficiência da ligação para transmissão de esforços solicitantes dependerá da disposição da armadura nessa região, das propriedades mecânicas destes concretos (CAR e UHPC) e também das condições de rugosidade da interface entre eles. Neste estudo é feita uma investigação do comportamento da interface do concreto pré-moldado (CAR) e o concreto de preenchimento (UHPC), considerando diferentes tipos de preparo de superfície do substrato. As rugosidades das superfícies foram quantificadas pelos métodos de medição por coordenadas e mancha de areia. Os ensaios realizados para investigação da resistência e rigidez na interface foram: tração na flexão, cisalhamento direto, cisalhamento inclinado e tração por compressão diametral. Notou-se que os parâmetros quantitativos da rugosidade tiveram pouca correlação com a resistência da interface. Além disso, observou-se que o ensaio de resistência à tração na flexão foi o mais representativo do comportamento da interface à tração. A resistência obtida nas interfaces (CAR-UHPC) foi 10% superior à resistência de ligações monolíticas de CAR utilizadas como referência nos ensaios de cisalhamento direto e inclinado. Os comportamentos de resistência e rigidez das interfaces foram bem representadas por um modelo numérico de contato. Conclui-se que o tipo de superfície realizada no CAR para receber o UHPC vai depender do esforço predominante na interface.
Titre en anglais
Interface study of precast concrete and ultra-high-performance reinforced concrete
Mots-clés en anglais
CAR
Interface
Numerical model
Roughness
UHPC
Resumé en anglais
The high-strength concrete (HSC) has used in the manufacture of precast concrete structures. One of the difficulties encountered in this building system is to establish a monolithic connection between the elements. The frequent solution is to fill with molding in situ using the CAR and a specific reinforcement arrangement. Currently, ultra-high-performance reinforced concrete (UHPC), with high mechanical properties (tensile and compressive strength) and good durability, appears as an option to fill in the region of the connection of these elements. In this case, the efficiency of the connection for transmission of efforts will depend on the arrangement of the reinforcement in that region, on the mechanical properties of these concretes (CAR and UHPC) and also on the roughness conditions of the interface between them. The study investigates the behavior of the precast concrete interface (CAR) and the filler concrete (UHPC), considering different types of substrate surface preparation. The surface roughness was quantified using the surface coordinate profile coordinates and sand patch test. The tests carried out to investigate the strength and stiffness at the interface were: flexural tensile, direct shear, slant shear and splitting tensile strength. It was noted that the quantitative parameters of the roughness had little correlation with the strength at the interface. Besides, it was observed that the flexural tensile strength test was the most representative of the behavior of the tensile interface. The strength obtained at the interfaces (CAR-UHPC) was 10% higher than the monolithic model in the direct shear and slant shear. The strength and stiffness behaviors of the interfaces were well represented by a numerical contact model. It is concluded that the type of surface made in the CAR to receive the UHPC will depend on the main effort at the interface.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-05-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs