• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2016.tde-21032016-101723
Documento
Autor
Nombre completo
Rogério Albuquerque Marques
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Costa, Isolda (Presidente)
Assis, Sergio Luiz de
Kunioshi, Clarice Terui
Melo, Hercilio Gomes de
Terada, Maysa
Título en portugués
Estudo da resistência à corrosão do aço inoxidável ferrítico AISI 444 para aplicação como biomaterial
Palabras clave en portugués
aços inoxidáveis
AISI 444
biomateriais
corrosão
próteses
Resumen en portugués
Os aços inoxidáveis ferríticos são naturalmente ferromagnéticos, o que impossibilita sua utilização em próteses ortopédicas. Apesar disso, em algumas aplicações específicas, faz-se necessário o uso de um biomaterial ferromagnético, como nas próteses odontológicas e faciais com conectores magnéticos. Este trabalho apresenta o estudo da resistência à corrosão e citotoxicidade do aço inoxidável ferrítico AISI 444, para avaliar seu potencial de uso como um biomaterial. O aço AISI 444 possui baixo teor de níquel, teores extrabaixos de intersticiais (C e N) e é estabilizado com Ti e Nb. Como materiais de referência foram utilizados o aço inoxidável austenítico ISO 5832-1 (ASTM F-138), por ser o biomaterial metálico mais empregado na fabricação de próteses ortopédicas, e uma base ferromagnética do sistema de fixação de próteses odontológicas, feita em aço inoxidável ferrítico (NeoM). O ensaio de citotoxicidade in vitro, pelo método de incorporação do corante vermelho neutro, revelou que o aço inoxidável AISI 444 não apresentou citotoxicidade. O comportamento frente à corrosão foi estudado por meio de curvas de polarização anódica potenciodinâmicas e espectroscopia de impedância eletroquímica (EIE). O meio de ensaio foi uma solução salina tamponada de fosfato (PBS), em condição naturalmente aerada e em fresta, a temperatura de 37 ºC. Para simular a condição de fresta dos ensaios eletroquímicos foi desenvolvido um novo equipamento. As propriedades eletrônicas do filme passivo foram avaliadas pela técnica de Mott-Schottky. Em meio aerado, os resultados de EIE indicaram que todos os materiais se mostraram passivos. As curvas de polarização indicaram que a resistência à corrosão por pite do aço AISI 444 foi equivalente à do aço ISO 5832-1, porém superior à do NeoM. Pelos diagramas de Mott-Schottky, conclui-se que o filme óxido no aço AISI 444 possui menor concentração de dopantes que o aço NeoM. Isto sugere que o aço AISI 444 apresenta maior resistência à transferência de carga através do filme passivo. Em condição de fresta, as polarizações indicaram taxas de corrosão baixas para ambos os aços, porém superiores para o aço ISO 5832-1, em comparação ao aço AISI 444. As micrografias das superfícies dos aços, após polarização, revelaram um maior ataque corrosivo no aço ISO 5832-1 do que no aço AISI 444. O aço NeoM apresentou composição química fora da especificação da norma. Os baixos teores de Cr e de Mo, além das altas concentrações de sulfetos, foram as prováveis causas da menor resistência à corrosão do NeoM, indicada pelos ensaios eletroquímicos. O equipamento proposto para avaliação da resistência à corrosão, em condição de fresta, mostrou boa reprodutibilidade de resultados. O aço inoxidável AISI 444 apresentou alta potencialidade para uso como biomaterial, especialmente na fabricação de componentes protéticos com fixação magnética.
Título en inglés
Study on the corrosion resistance of AISI 444 stainless steel for application as biomaterial
Palabras clave en inglés
AISI 444
biomaterials
corrosion
phrostesis
stainless steels
Resumen en inglés
Ferritic stainless steels are ferromagnetic materials. This property does not allow their use in orthopedic prosthesis. Nevertheless, in some specific applications, this characteristic is very useful, such as, for fixing dental and facial prostheses by using magnetic attachments. In this study, the corrosion resistance and cytotoxicity of the AISI 444 ferritic stainless steel, with low nickel content, extra-low interstitial levels (C and N) and with the addition of Ti and Nb as stabilizers, were investigated to evaluate its potentiality for biomaterials fabrication. The ISO 5832 austenitic stainless steel (SS) and a commercial universal keeper for dental attachment (Neo-magnet System) were evaluated for comparison reasons. The first stainless steel is the most used metallic material for orthopedic prostheses fabrication, and the second one, is a ferromagnetic keeper for dental prostheses (NeoM). In vitro cytotoxicity analysis was performed by the red neutral incorporation method. The results showed that the AISI 444 stainless steel is non cytotoxic. The corrosion resistance was studied by anodic polarization methods and electrochemical impedance spectroscopy (EIS), in a saline phosphate buffered solution (PBS) at 37 °C, either naturally aerated or under crevice condition. A new device was developed to simulate the crevice condition on electrochemical tests. The electronic properties of the passive film formed on AISI 444 SS were evaluated by the Mott-Schottky approach. All tested materials showed passivity in the PBS medium and the passive oxide film presented a duplex nature. In aerated condition, the resistance to pitting corrosion associated to AISI 444 SS was similar to that of the ISO 5832 SS and both were superior to that of the NeoM SS. The 444 SS oxide film showed lower dopants concentration than the NeoM SS, suggesting that the 444 SS film presents a higher resistance to charge transfer through it than the fim on the NeoM SS. Under crevice conditions, the potentiodinamic polarization tests indicated low corrosion rates for both steels, but slightly higher for the ISO 5832 SS when compared to the AISI 444 SS tested. Observation of the surface, after crevice polarization, indicated a larger area of corrosive attack on the ISO 5832-1 SS than on the AISI 444 SS.The chemical composition of the NeoM SS was out of the standard specification. The low levels of Cr and Mo in the NeoM, and the high concentration of MnS precipitates, are the probable cause of its lower corrosion resistance. The new devide proposed for crevice corrosion resistance evaluation, showed good reproducibility of results.The AISI 444 stainless steel showed a high potential for use as a biomaterial, especially for the manufacture of prosthetic components with magnetic attachment.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2014MarquesEstudo.pdf (5.79 Mbytes)
Fecha de Publicación
2016-03-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.