Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2016.tde-04032016-112713
Document
Auteur
Nom complet
Elaine Pereira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Pires, Maria Aparecida Faustino (Président)
Cotrim, Marycel Elena Barboza
Figueiredo, Ana Maria Graciano
Pedreira Filho, Walter dos Reis
Saito, Renata Mayumi
Titre en portugais
Desenvolvimento e validação de metodologia analítica para quantificação de urânio em compostos do ciclo do combustível nuclear por espectroscopia no infravermelho com transformada de Fourier (FTIR)
Mots-clés en portugais
ciclo do combustível nuclear
espectroscopia infravermelho
FTIR
urânio
validação analítica
Resumé en portugais
Este trabalho apresenta uma nova metodologia, simples e de baixo custo, para quantificação direta de urânio em compostos do ciclo do combustível nuclear, baseada na espectroscopia no infravermelho com transformada de Fourier (FTIR), utilizando a técnica de pastilhamento em KBr. Diferentes matrizes foram utilizadas para o desenvolvimento e validação analítica: nitrato de uranilo complexado com TBP (UO2(NO3)2.2TBP) em fase orgânica e nitrato de uranilo (UO2(NO3)2) em fase aquosa. O método para matriz de urânio em fase orgânica (UO2(NO3)2.2TBP em hexano/incorporado em KBr) apresentou linearidade (r = 0,9980) dentro da faixa analítica de 0,20% 2,85% de urânio na pastilha de KBr, LD de 0,02% e LQ de 0,03%, exatidão com recuperações acima de 101,0%, robustez e precisão (DPR < 1,6%). O método para matriz de urânio em fase aquosa (UO2(NO3)2/incorporado em KBr) apresentou linearidade (r = 0,9900) dentro da faixa analítica de 0,14% 0,29% de urânio na pastilha de KBr, LD de 0,01% e LQ de 0,02%, exatidão com recuperações acima de 99,4%, robustez e precisão (DPR < 1,6 %). Amostras de processo do ciclo do combustível nuclear foram submetidas a avaliação intralaboratorial e os resultados foram comparados estatisticamente por outras técnicas: Espectrometria de Fluorescência de Raios-X (FRX) e gravimetria. Os testes estatísticos (t-Student e Fischer) indicaram que a técnica por FTIR e as de referência são equivalentes, demonstrando que a nova metodologia pode ser empregada com sucesso nas análises de rotina para o controle de qualidade dos compostos nucleares.
Titre en anglais
Analitycal method development and validation for quantification of uranium in compounds of the nuclear fuel cycle by fourier transform infrared (FTIR) spectroscopy
Mots-clés en anglais
analytical validation
FTIR
infrared spectroscopy
nuclear fuel cycle
uranium
Resumé en anglais
This work presents a low cost, simple and new methodology for direct quantification of uranium in compounds of the nuclear fuel cycle, based on Fourier Transform Infrared (FTIR) spectroscopy using KBr pressed discs technique. Uranium in different matrices were used to development and validation: UO2(NO3)2.2TBP complex (TBP uranyl nitrate complex) in organic phase and uranyl nitrate (UO2(NO3)2) in aqueous phase. The parameters used in the validation process were: linearity, selectivity, accuracy, limits of detection (LD) and quantitation (LQ), precision (repeatability and intermediate precision) and robustness. The method for uranium in organic phase (UO2(NO3)2.2TBP complex in hexane/embedded in KBr) was linear (r = 0.9980) over the range of 0.20% 2.85% U/ KBr disc, LD 0.02% and LQ 0.03%, accurate (recoveries were over 101.0%), robust and precise (RSD < 1.6%). The method for uranium aqueous phase (UO2(NO3)2/embedded in KBr) was linear (r = 0.9900) over the range of 0.14% 1.29% U/KBr disc, LD 0.01% and LQ 0.02%, accurate (recoveries were over 99.4%), robust and precise (RSD < 1.6%). Some process samples were analyzed in FTIR and compared with gravimetric and X-ray fluorescence (XRF) analyses showing similar results in all three methods. The statistical tests (t-Student and Fischer) showed that the techniques are equivalent. The validated method can be successfully employed for routine quality control analysis for nuclear compounds.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-03-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.