Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2008.tde-13102011-134400
Document
Author
Full name
Claudio Boghi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2008
Supervisor
Committee
Rela, Paulo Roberto (President)
Costa, Fábio Eduardo da
Karam Junior, Dib
Title in Portuguese
Desenvolvimento de procedimentos e metodologia de controle para aplicação de boas práticas de fabricação (BPF) na irradiação de sangue humano
Keywords in Portuguese
fontes de irradiação
leucócitos
radiação gama
sangue
Abstract in Portuguese
A irradiação do sangue humano é usada para evitar a TA-DECH ("transfusão associada a doença do enxerto contra hospedeiro"), um raro mas devastador efeito adverso dos leucócitos presentes em componentes de sangue de doadores. Normalmente esta prática de irradiação é executada para a eliminação física de leucócitos. A implementação de procedimentos permitirá que a dose apropriada, dentro de uma faixa de 25 Gy a 50 Gy, seja absorvida pelas bolsas de sangue coletadas em um banco de sangue. Os estudos para estabelecer os procedimentos de BPF (Boas Práticas de Fabricação) foram desenvolvidos baseados na norma ISO 11137 Esterilização de produtos médicos Requisitos para validação e controle de rotina Esterilização por radiação. Dois sistemas dosimétricos foram usados para o mapeamento de dose durante os estudos da qualificação do irradiador, carregamento de produto, validação de processo de irradiação e auditoria. O dosímetro CaSO4:Dy apresentou dificuldades em relação à incerteza na medição da dose, estabilidade, rastreabilidade e calibração. Os dosímetros PMMA e Gafchromic mostraram uma melhor performance e foram adotados para estudos de qualificação de irradiadores necessários para a implantação de BPF. Os testes de irradiação foram realizados em um irradiador Gammacell 220. Os procedimentos desenvolvidos podem ser adaptados para diferentes tipos de irradiadores gama, permitindo a implantação de um programa de garantia da qualidade e BPF para irradiação de sangue.
Title in English
Procedures development and methodology of control for application of good manufacture practices (GMP) on human blood irradiation
Keywords in English
blood
gamma radiation
host
irradiation procedures
irradiation sources
leukocytes
management
thermoluminescent dosemeters
Abstract in English
The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immunocompetent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of leukocytes. The implementation of the procedures will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies of the procedures in order to establish a GMP (Good Manufacturing Practices) were developed under the guidelines of the standard ISO 11137 Sterilization of health care products Requirements for validation and routine control Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO4:Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, traceability and calibration. The PMMA and Gafchromic dosimetric systems have shown a better performance and were adopted on studies of irradiators qualification that are necessary to implementation of GMP. The irradiation tests have been done in a Gammacell 220 irradiator. The developed procedures can be adapted for different kinds of gamma irradiators, allowing implanting a quality assurance program and a GMP for blood irradiation.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-10-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.