• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2013.tde-10022014-105712
Document
Auteur
Nom complet
Adélia Aparecida Yuka Kakoi
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2013
Directeur
Jury
Moralles, Mauricio (Président)
Rodrigues Junior, Orlando
Yoshimura, Elisabeth Mateus
Titre en portugais
Análise da metodologia de calibração dos detectores de NaI(Tl) do Laboratório de Monitoração in vivo do IPEN pelo método de Monte de Carlo
Mots-clés en portugais
dosimetria interna
Método de Monte Carlo
monitoração in vivo
PENELOPE
Resumé en portugais
Esse trabalho avalia a metodologia utilizada pelo Laboratório de Monitoração in vivo (LMIV) do IPEN na calibração dos detectores de NaI(Tl) pelo código PENELOPE- penEasy, baseado no Método de Monte Carlo. Inicialmente, foram realizadas simulações sem o simulador antropomórfico com o objetivo de encontrar uma geometria que representasse adequadamente os detectores para exames de corpo inteiro e de tireoide. A aquisição dos dados experimentais foi realizada pelo software GENIE, que é utilizado na rotina do laboratório e as áreas dos fotopicos foram calculadas pelos softwares GENIE e GNUPLOT e pelo método descrito no Ciemat Technical Report, que também fornece os valores de eficiência de fotopico. Fontes de 60Co, 137Cs, 152Eu, 207Bi e 241Am calibradas foram utilizadas nas medições. Os resultados mostraram que o software GENIE é apropriado para ser utilizado nas calibrações de rotina e fontes que possuam picos isolados e definidos pelo detector de NaI(Tl), são ideais para serem utilizadas nas calibrações em eficiência. A simulação MC indica que é possível substituir calibrações experimentais por simulações utilizando uma geometria simplificada do detector de NaI(Tl), mas as grandezas relevantes como a fonte, o detector e o sistema eletrônico devem ser conhecidos com detalhes para que as fontes de erros sistemáticos sejam as menores possíveis.
Titre en anglais
Analysis of the calibration methods of NaI(Tl) detectors at the in vivo monitoring laboratory of ipen using the Monte Carlo Method
Mots-clés en anglais
in vivo monitoring
internal dosimetry
Monte Carlo Method
PENELOPE
Resumé en anglais
The calibration methods of NaI(Tl) detectors of the in vivo Monitoring Laboratory (LMIV) of IPEN were analyzed by comparing experimental results with simulations performed with the PENELOPE- penEasy Monte Carlo radiation program. The first simulations were performed without the anthropomorphic simulator aiming to find a simplified detector geometry that could represent the whole body and thyroid detectors. The data acquisition was performed with the GENIE software, which is used in the laboratory routine, and the photopeak areas were calculated with the GENIE and GNUPLOT softwares as well as using the method described on the Ciemat Technical Report. Standard sources of 60Co, 137Cs, 152Eu, 207Bi and 241Am were used in the measurements. The results show that GENIE is a suitable software to be used in the laboratory routine and ideal sources are those that present isolated and well-defined photopeaks in the spectra measured with NaI(Tl) detectors. The Monte Carlo study reveals that the simplified models of the NaI detectors are able to provide a full- energy peak efficiency curve but it is necessary to know all details of the significant quantities as the source, the detector and the electronics in order to minimize sources of systematic errors.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
2013KakoiAnalise.pdf (3.62 Mbytes)
Date de Publication
2014-02-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.