• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2011.tde-01072011-133729
Document
Author
Full name
Fabricio Fernandes Vaz da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Dias, Mauro da Silva (President)
Medeiros, José Agostinho Gonçalves de
Normanton, Kátia Aparecida Fonseca
Title in Portuguese
Medida absoluta da atividade e determinação da probalidade de emissão gama por decaimento do 177 Lu
Keywords in Portuguese
coincidência
lutécio-177
Monte Carlo
padronização
probabilidade de emissão gama
Abstract in Portuguese
O presente trabalho teve como objetivo a padronização em atividade do radionuclídeo 177Lu, um importante radiofármaco utilizado no tratamento de câncer neuroendócrino. Este radionuclídeo se desintegra por emissão beta acompanhada de várias emissões gama simultâneas, o que tornou possível a aplicação do método de coincidência 4πβ-γ. Para a detecção da radiação beta, foi utilizado um detector proporcional (PC), com geometria 4π e dois cintiladores de NaI(Tl) para a detecção da radiação gama. Os sinais gerados nos detectores passaram por amplificadores, discriminadores e módulos atrasadores, para serem enviados a um analisador multicanal. Para este experimento, foi utilizado um sistema de coincidências que aplica um módulo TAC (Time to Amplitude Converter), o qual converte diferença de tempo em amplitude de pulso. Para obter-se a variação na eficiência beta, foram acrescentados absorvedores de Collodion nas partes superior e inferior da fonte radioativa. Desta forma, foi possível extrapolar o valor para eficiência beta igual a 100%, obtendo assim a atividade da fonte radioativa. A curva de extrapolação experimental foi comparada com a previsão teórica, obtida por meio do método de Monte Carlo. Além da padronização em atividade do 177Lu, também foram determinadas as suas probabilidades de emissão gama por decaimento para cada uma das principais transições gama, por meio de um espectrômetro de HPGe, previamente calibrado.
Title in English
Absolute activity measurement and determination of gamma-ray emission probability per decay of 177Lu
Keywords in English
gamma-ray emission probabilities
Monte Carlo
standardization
Abstract in English
The present work aimed the activity standardization of radionuclide 177Lu, an important radioisotope used for treatment of neuroendocrine cancer. This radionuclide disintegrates by beta decay followed by several simultaneous gamma-ray emissions, which made possible the application of the 4πβ-γ coincidence method. For the detection of beta radiation in 4π geometry a proportional detector (PC) was used, and for gamma radiation detection a pair of NaI(Tl) scintillators was used. The signals generated by the detectors passed through amplifiers, discriminators and delay modules, and were sent to a multichannel analyzer. For the present experiment, the system includes a TAC (Time to Amplitude Converter) module which converts the time difference in pulse amplitude. To obtain the variation in beta efficiency, Collodion absorbers at the top and bottom of the radioactive source were applied. In this way, it was possible to extrapolate the beta efficiency value to 100%, thereby obtaining the radioactive source activity. The extrapolated experimental curve was compared with the theoretical prediction, obtained by means of the Monte Carlo method. Besides the activity standardization of 177Lu, its gamma-ray emission probabilities per decay for the main gamma transitions were also determined by means of an HPGe spectrometer, previously calibrated.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2011SilvaMedida.pdf (1.32 Mbytes)
Publishing Date
2011-08-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.