• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2010.tde-01022011-162926
Documento
Autor
Nome completo
Lais Vissotto Garchet Santos Reis
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2010
Orientador
Banca examinadora
Chalela, William Azem (Presidente)
Cesar, Luiz Antonio Machado
Costa, Ricardo Vivacqua Cardoso
Mastrocolla, Luiz Eduardo
Sapienza, Marcelo Tatit
Título em português
Efeito da cafeína na detecção de isquemia à cintilografia de perfusão miocárdica associada ao estresse com adenosina
Palavras-chave em português
Adenosina/uso diagnóstico
Cafeína/administração e dosagem
Imagem por perfusão do miocárdio
Vasodilatadores
Resumo em português
A utilização da cintilografia de perfusão miocárdica (CPM) estava limitada a pacientes que podiam realizar algum tipo de exercício, para ampliarmos a disponibilidade clínica da CPM, vários protocolos com estresses farmacológicos foram desenvolvidos. A adenosina fármaco amplamente utilizado, potente vasodilatador coronariano, apresenta uma importante interação com outras substâncias que anatagonizam seus efeitos, o dipiridamol, alimentos com cafeína e derivados de xantinas. O tempo de suspensão de cafeína da dieta para o uso exógeno da adenosina na realização da CPM ainda não está definido. Para testar essa hipótese avaliamos a influência da abstinência de cafeína em 24h, 12h e 1h, através de sua dosagem sérica, antes do estresse farmacológico com adenosina e sua possível repercussão nas imagens da CPM e o efeito vasodilatador no sistema cardiovascular. Definimos como objetivo primário: comparar a presença e a extensão dos defeitos reversíveis da CPM verificados em pacientes com abstinência de café por 24 horas (E1) com as imagens da randomização com 1 hora e 12 horas (E2) sem cafeína e como objetivos secundários: avaliar a presença e intensidade dos paraefeitos, comportamento da frequência cardíaca e da pressão arterial sistêmica. Foram submetidos ao estresse farmacológico com adenosina 194 pacientes para a realização da CPM, dos quais 43 pacientes preencheram os critérios para a randomização (defeitos perfusionais transitórios na CPM com adenosina). Excluímos seis pacientes (13,9%), três (6,9%) se recusaram a realizar a fase da randomização e os outros três (6,9%) nos quais não houve consenso entre os observadores em relação aos defeitos de perfusionais transitórios. A média de idade dos 37 pacientes analisados foi de 61,4 ± 8,3 anos, sendo 21 pacientes do sexo masculino (56,8%). Na avaliação das imagens da CPM, não houve diferença entre as imagens obtidas no grupo E1 comparadas as imagens de 1 (2,0 ± 1,5) hora ou 12 (12,6 ± 3,1) horas sem cafeína (E2). As médias de cafeína sérica encontradas foram de 0,14 ± 0,17 mg/l no grupo E1 do E2 de 1 hora e 0,13 ± 0,24 mg/l no grupo E1 do E2 de 12 horas, na randomização de 1 hora de 1,97± 0,83 mg/l e de 12 horas de 1,51 ± 1,46 mg/l (E1 vs. E2: p < 0,001). Em relação à presença dos paraefeitos, ocorreram em 31 pacientes (83,7%) e os mais freqüentes foram: dor precordial atípica, cansaço e dor em região cervical. Não foram observadas diferenças em relação às freqüências absolutas e relativas na ocorrência de paraefeitos entre os grupos. A intensidade dos paraefeitos foi verificada através de análise subjetiva comparando os sintomas em relação aos exames. Notou-se que em 22 pacientes (59,4%), caracterizaram o estudo randomizado como bem melhor, ou melhor, que o de 24 horas. A pressão arterial sistêmica e a freqüência cardíaca também não apresentaram diferenças entre os grupos. Conclusões: Os resultados permitem inferir que o uso da cafeína ingerida 2 horas antes da realização da CPM com adenosina foi eficaz e segura, pois apesar da modificação da resposta vasodilatadora máxima alcançada, traduzida pela melhor tolerância do exame realizado com menos tempo de ausência de cafeína na dieta, não modificou o resultado final da CPM
Título em inglês
Effects of caffeine on ischemia detection in myocardial perfusion scyntigraphy induced by adenosine stress
Palavras-chave em inglês
Adenosine/diagnostic use
Caffeine/administration and dosage
Image by myocardial perfusion and determination
Vasodilators
Resumo em inglês
Myocardial perfusion imaging (MPI) in the past was only available to patients who were able to perform some type of exercise. Many protocols were developed with pharmacologic stress in order to enlarge the clinical availability of myocardial perfusion imaging (MPI). Adenosine is widely used and a potent coronary vasodilator, exhibits a significant interaction with other substances which antagonize its effects, such as dipyridamole, food products containing caffeine and xanthine derivatives. We found no clear consensus as to the time between caffeine ingestion and a cardiovascular adenosine stress test. To test this hypothesis we evaluated the influence of 24-hour, 12-hour and 1-hour caffeine abstinence, by assessing plasma caffeine levels before adenosine pharmacological stress, the possible repercussions on MPI images and vasodilatory effects on the cardiovascular system. The primary endpoint was to compare the presence and extent of reversible myocardial perfusion defects found in patients with 24-hour abstinence from coffee (E1), with images from patients randomized to 1-hour or 12-hour caffeine abstinence (E2). As secondary endpoints we evaluated the presence and intensity of paraeffects, as well as heart rate and systemic arterial blood pressure behavior. For this purpose, 194 patients underwent pharmacological stress with adenosine for MPI, 43 of whom fulfilled criteria for randomization (patients with transient perfusion defects detected on adenosine MPI). Six patients were excluded (13.9%), three patients (6.9%) who refused to undergo randomization, and other three (6.9%) in whom the observers could not reach consensus regarding transient perfusion defects. Mean age for the 37 patients analyzed was 61.4 ± 8.3 years, 21 patients male (56.8%). In the evaluation of myocardial perfusion images, no differences were detected between images obtained in the 24-hour E1 arm, and those from 1 (2.0 ± 1.5) hour or 12 (12.6 ± 3.1) hours randomization E2. Mean plasma caffeine level was 0.14 ± 0.17 mg/l in group E1 of the 1-hour arm E2, and 0.13 ± 0.24 mg/l in group (E1) of the 12-hour arm (E2), respectively, compared with 1.97± 0.83 mg/l, in the 1-hour, and 1.51 ± 1.46 mg/l, in the 12-hour (E2) randomized arms (E1 vs. E2: p < 0.001). In the 31 patients (83.7%) with presence of paraeffects, the most frequent were: atypical precordial pain, tiredness and pain on cervical area. There were no differences in the absolute and relative frequency in the occurrence of paraeffects between groups. However, with respect to the intensity of pareffects, a subjective analysis was undertaken, comparing symptoms of two exams. which resulted in 22 patients (59.4%) ranking the randomized study a lot better, or better than the 24-hour one. The systemic blood pressure and the heart rate behavior also did not reveal any significant differences between groups. Conclusions: The results may imply that the use of caffeine ingested 2 hours prior to the CPM with adenosine was effective and safe, for despite the change in maximal vasodilator response achieved, manifested by better tolerance of the examination with less time in the absence of caffeine in the diet, did not change the final result of the CPM
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2011-02-02
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.