• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.42.2016.tde-24022016-114730
Document
Auteur
Nom complet
Leandro Jorge da Silva
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Schneider, Rene Peter (Président)
Gomez, José Gregorio Cabrera
Melo, Hercilio Gomes de
Sato, Maria Inês Zanoli
Silva, Luiziana Ferreira da
Titre en portugais
Corrosão microbiologicamente influenciada em superfícies metálicas expostas à água de processo industrial de usinas hidrelétricas.
Mots-clés en portugais
Biofilmes
Biofouling
Corpos de Prova
Corrosão Microbiológica
Taxas de Corrosão
Usinas Hidrelétricas
Resumé en portugais
Materiais metálicos expostos a ambientes aquáticos estão susceptíveis ao desenvolvimento de Corrosão Microbiologicamente Influenciada (CMI). Nas indústrias a CMI é um assunto de extrema importância devido aos prejuízos gerados nos reparos ou trocas de equipamentos e nas interrupções dos sistemas de produção associadas às falhas técnicas. No presente trabalho estão apresentados resultados de um estudo de CMI em superfícies metálicas expostas à água de processo em uma unidade geradora de energia hidrelétrica, que sofre com um acelerado processo corrosivo, principalmente nos trocadores de calor e nas turbinas. A partir de biofilmes de corrosão amostrados nas turbinas e trocadores de calor foram isolados grupos bacterianos redutores de sulfato e oxidantes e redutores de ferro que foram relacionadas como indutoras/ agravantes do processo corrosivo.
Titre en anglais
Biocorrosion on metal surfaces in hydroelectric power plant.
Mots-clés en anglais
Biofilms
Biofouling
Corrosion Rates
Coupons
Hydroelectric Power Plants
Microbial Corrosion
Resumé en anglais
Metallic materials exposed to aquatic environments are susceptible to development of Microbiologically Influenced Corrosion (MIC). In industries MIC is a matter of great importance due to damages generated in repairs or equipment changes and production systems disruptions associated with technical failures. In this work are presented results of a MIC study on metal surfaces exposed to process water in a generating unit of hydropower, which suffers from an accelerated corrosion process, especially in the heat exchangers and the turbines. From corrosion biofilms sampled in turbines and heat exchangers were isolated bacterial groups sulfate reducing and oxidizing and reducing iron. These bacteria have been widely reported in the literature as inducing / aggravating the corrosion process.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-03-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.