• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.42.2016.tde-24022016-114730
Documento
Autor
Nombre completo
Leandro Jorge da Silva
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Schneider, Rene Peter (Presidente)
Gomez, José Gregorio Cabrera
Melo, Hercilio Gomes de
Sato, Maria Inês Zanoli
Silva, Luiziana Ferreira da
Título en portugués
Corrosão microbiologicamente influenciada em superfícies metálicas expostas à água de processo industrial de usinas hidrelétricas.
Palabras clave en portugués
Biofilmes
Biofouling
Corpos de Prova
Corrosão Microbiológica
Taxas de Corrosão
Usinas Hidrelétricas
Resumen en portugués
Materiais metálicos expostos a ambientes aquáticos estão susceptíveis ao desenvolvimento de Corrosão Microbiologicamente Influenciada (CMI). Nas indústrias a CMI é um assunto de extrema importância devido aos prejuízos gerados nos reparos ou trocas de equipamentos e nas interrupções dos sistemas de produção associadas às falhas técnicas. No presente trabalho estão apresentados resultados de um estudo de CMI em superfícies metálicas expostas à água de processo em uma unidade geradora de energia hidrelétrica, que sofre com um acelerado processo corrosivo, principalmente nos trocadores de calor e nas turbinas. A partir de biofilmes de corrosão amostrados nas turbinas e trocadores de calor foram isolados grupos bacterianos redutores de sulfato e oxidantes e redutores de ferro que foram relacionadas como indutoras/ agravantes do processo corrosivo.
Título en inglés
Biocorrosion on metal surfaces in hydroelectric power plant.
Palabras clave en inglés
Biofilms
Biofouling
Corrosion Rates
Coupons
Hydroelectric Power Plants
Microbial Corrosion
Resumen en inglés
Metallic materials exposed to aquatic environments are susceptible to development of Microbiologically Influenced Corrosion (MIC). In industries MIC is a matter of great importance due to damages generated in repairs or equipment changes and production systems disruptions associated with technical failures. In this work are presented results of a MIC study on metal surfaces exposed to process water in a generating unit of hydropower, which suffers from an accelerated corrosion process, especially in the heat exchangers and the turbines. From corrosion biofilms sampled in turbines and heat exchangers were isolated bacterial groups sulfate reducing and oxidizing and reducing iron. These bacteria have been widely reported in the literature as inducing / aggravating the corrosion process.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-03-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.