Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2019.tde-29052019-103457
Documento
Autor
Nombre completo
Luis Carlos Timana Eraso
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2019
Director
Tribunal
Zanetta Junior, Luiz Cera (Presidente)
Campos, Victor Augusto Fernandes de
Moreira, Fernando Augusto
Título en portugués
Análise de modelos de linhas de transmissão com parâmetros variantes com a frequência.
Palabras clave en portugués
Energia
Linhas aéreas de transmissão de energia elétrica
Modelos matemáticos
Transformada de Fourier
Resumen en portugués
Neste trabalho são descritos e avaliados diferentes modelos de linhas aéreas de transmissão, considerando a variação dos parâmetros da linha com a frequência. Em geral os modelos apresentados são baseados no uso da matriz de admitâncias nodais, com algumas análises complementares empregando o método das características. São testados casos de circuito-aberto, curto-circuito, linha em carga e manobras com chaves. Os resultados de cálculo são comparados com as respostas simuladas nos programas ATP e PSCAD. Também são apresentadas as formulações para o cálculo de parâmetros da linha de transmissão, considerando o efeito pelicular e a resistividade do solo São avaliadas as respostas no domínio do tempo para diferentes modelos equivalentes de linha de transmissão, obtidos do modelo polo-resíduo com passividade da matriz de admitâncias nodais, sendo empregados: i) transformação do modelo racional para uma representação em espaço de estados, ii) construção de uma rede elétrica equivalente com resistências, indutores e capacitores e iii) representação por meio de um equivalente de Norton. Também é analisado o equivalente de Norton obtido dos modelos polo-resíduo com passividade de uma linha equivalente dobrada nas condições em curto-circuito e circuito-aberto. Foi analisada a solução de redes elétricas no domínio da frequência usando uma formulação nodal e sem a necessidade de ajustes intermediários da matriz de admitâncias nodais. As respostas de tensão e corrente são antitransformadas para o domínio do tempo por meio de diferentes formulações baseadas na transformada inversa de Fourier, levando em conta os métodos que mitigam erros de truncamento e discretização. As seguintes formulações foram avaliadas: i) transformada modificada de Fourier, ii) transformada inversa rápida de Fourier e iii) transformada inversa de Fourier com integração semianalítica. É também apresentado um modelo para linhas de transmissão em paralelo, baseado no domínio modal usando uma matriz de transformação constante, juntamente com a aplicação do método de ajuste Vector Fitting com o objetivo de modelar com precisão o efeito de acoplamento mútuo entre linhas.
Título en inglés
Transmission lines models with frequency dependent parameters.
Palabras clave en inglés
Electromagnetic transients
Inverse Fourier transform
Nodal admittance matrix
Passivity enforcement
Transmission lines
Vector fitting
Resumen en inglés
In this work different overhead transmission lines models are described and evaluated, considering the frequency dependence of parameters. In general, the models are based on the nodal admittance matrix, with some complementary analysis using the method of characteristics. Cases of open-circuit, short-circuit, line connected to a load and switching maneuvers are tested. The calculation results are compared with the simulated responses obtained with the ATP and PSCAD. The formulations for the transmission line parameters are also presented, taking into account the skin effect and the ground return. The time-domain responses for different transmission line models are evaluated. These models are obtained from the passive pole-residue model of the nodal admittance matrix. The equivalent models are: i) state-space representation, ii) electrical network composed of resistors, inductors and capacitors, iii) the Norton's equivalent. In addition, an evaluation is performed for the Norton's equivalent obtained from the pole-residue models for the open-circuit and short-circuit conditions of a folded line equivalent. On the other hand, the network is solved completely in frequency-domain using a nodal formulation, without the fitting of the nodal admittance matrix. The voltage and current responses are transformed back to the time-domain by different formulations based on the inverse Fourier transform, taking into account methods to minimize errors by truncation and discretization. The formulations investigated are: i) modified Fourier transform, ii) fast Fourier transform, iii) inverse Fourier transform with semianalytic integration. The model for parallel transmission lines is also evaluated, based on modal domain using a constant transformation matrix and the application of the vector fitting method, with emphasis on accurate representation of mutual coupling effects.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-05-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.