• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2012.tde-26042012-100422
Document
Author
Full name
Geraldo Lupi Filho
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Altafim, Ruy Alberto Corrêa (President)
Ahn, Se Un
Silva, Ivan Nunes da
Title in Portuguese
Comparação entre os critérios de diagnósticos por análise cromatográfica de gases dissolvidos em óleo isolante de transformador de potência
Keywords in Portuguese
Análise de gases dissolvidos
Cromatografia gasosa
Método de detecção de falhas
Transformador de potência
Abstract in Portuguese
Existem inúmeras ferramentas e metodologias para o diagnóstico de falhas em transformadores de potência, tanto para a monitoração e acompanhamento do equipamento em operação (planta fixa) como àquele retirado e abrigado em laboratórios de unidades fabris. Em função dos custos envolvidos no transporte dos equipamentos, manuseio para a substituição, energia não faturada nos períodos de manobras e custos adicionais dos ensaios para voltar com o equipamento em operação, as principais metodologias que se destacam são aquelas direcionadas ao equipamento em operação e também as escolhidas para serem analisadas neste trabalho. Após um estudo sistemático dessas metodologias, tais como termográfica, emissão acústica e análise dos gases dissolvidos no óleo, denominada cromatografia, verificou-se que esta última se destaca como a mais econômica e a mais difundida na identificação das falhas. Contudo, na cromatografia, existem diferentes critérios de análise baseados nas relações e quantidades de diferentes tipos de gases e que são usados pelas companhias concessionárias de forma indiscriminada, gerando muitas dúvidas quanto à sua validade. Esta pesquisa teve como principal foco a comparação desses critérios usando como base de dados àqueles fornecidos pela IEC e pela Companhia Paulista de Força e Luz (CPFL). A base de dados da CPFL contem aproximadamente quatro mil ensaios cromatográficos, colhidas nas ultimas três décadas correspondendo a 500 unidades transformadoras, nas potências de 5,0 a 50 MVA, instaladas em subestações nas tensões primárias de 69 e 138 kV, e secundária de 13,8 kV. Também fez parte dessa pesquisa a definição de um conjunto de critérios que melhor identificam as falhas em transformadores.
Title in English
Comparison between the diagnostic criteria for chromatographic analysis of gases dissolved in insulating oil for transformer
Keywords in English
Dissolved gas analysis
Gas chromatography
Method of fault detection
Power transformer
Abstract in English
There are numerous tools and methodologies for fault diagnosis in power transformers, either for monitoring and tracking equipment in operation (fixed plant) or for those removed and housed in laboratories plants. Due to the costs involved in transporting the equipment, handling for the replacement, unbilled energy during periods of maneuvers and additional costs of the tests to return with the equipment in operation, the main methodologies that stand out are those using the equipment in operation and also those chosen to be analyzed in this work. After a systematic study of these methods such as thermography, and acoustic emission and analysis of gases dissolved in the oil, known as chromatography, it was found that the latter stands out as the most economical and most widely in the identification of faults. However, in chromatography, there are different criteria based on the relationships of different types and quantities of gases that are used by electrical companies indiscriminately, raising many questions about its validity. This research was mainly focused on the comparison of these criteria using the database as those provided by IEC and the Companhia Paulista de Força e Luz (CPFL). The database of CPFL contains approximately four thousand chromatographic assays from the last three decades, corresponding 500 transforming units, from 5 to 50 MVA, in substations with primary voltages of 138 kV and 69 and secondary of 13,8 kV. Was also studied the definition of a set of criteria which identify faults in transformers.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Geraldo.pdf (7.13 Mbytes)
Publishing Date
2012-05-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.