Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2010.tde-28122010-131829
Document
Auteur
Nom complet
Ana Flávia Silveira Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2010
Directeur
Jury
Marra Junior, Wiclef Dymurgo (Président)
Aguiar, Monica Lopes
Caram, Rosana Maria
Titre en portugais
Avaliação da qualidade ambiental interior de um edifício climatizado artificialmente com ênfase na análise do conforto térmico
Mots-clés en portugais
Condicionamento de ar
Conforto térmico
Distribuição de ar pelo piso
Qualidade ambiental interior
Qualidade do ar interior
Síndrome dos edifícios doentes
Resumé en portugais
Ocupantes de ambientes internos climatizados artificialmente estão expostos contínua e prolongadamente a condições ambientais muitas vezes desfavoráveis à execução de suas atividades e à manutenção da saúde. O objetivo desta pesquisa foi avaliar alguns parâmetros de qualidade do ar interior e de conforto térmico de um edifício climatizado artificialmente e relacioná-los à utilização de sistema de condicionamento de ar com distribuição pelo piso em ambientes que não são caracterizados como escritórios abertos. Considerando que o edifício estudado apresenta usos distintos de seus pavimentos, optou-se pela avaliação de dois deles, um pavimento cujo layout é de salas de aula e outro de escritório semi-aberto. Os parâmetros foram analisados em três momentos distintos. O primeiro se caracteriza por três ciclos semestrais de medições de temperatura, umidade relativa e velocidade do ar, concentração de aerossóis, dióxido de carbono e fungos. A segunda etapa consiste em uma campanha única de medições, com duração de quatro dias, permitindo a realização de perfis de temperatura e umidade relativa, avaliação das velocidades do ar em pontos de desconforto e cálculo dos índices de conforto térmico PMV (Predicted Mean Vote) e PPD (Predicted Percentage of Dissatisfied). Em um terceiro e último momento, aplicou-se o questionário de qualidade ambiental interior aos ocupantes de ambos os pavimentos. Resultados obtidos nos ciclos permitiram identificar concentrações de fungos e dióxido de carbono acima dos limites indicados. Os perfis de temperatura revelaram a predominância das mesmas abaixo do recomendado. O cálculo dos índices PMV e PPD apontaram para um cenário de maior conforto térmico nos ambientes estudados com temperatura operativa igual a 24 graus Celsius. Os resultados dos questionários corroboraram as medições de temperatura, indicando a prevalência das sensações térmicas relacionadas ao frio entre os ocupantes do edifício, em especial aqueles do sexo feminino. Ficou evidenciado que o conforto térmico nos ambientes pesquisados é um fator perturbador das atividades exercidas em ambos os pavimentos. Houve um grande número de relatos de ocupantes com sintomas típicos da Síndrome dos Edifícios Doentes (SED), sugerindo que medidas relativas à qualidade ambiental devem ser tomadas em prol da saúde, bem estar e produtividade dos ocupantes do edifício. Concluiu-se que a operação e manutenção do sistema de condicionamento de ar com insuflamento pelo piso em ambientes distintos de escritórios abertos são mais complexas e, por isso, dificultam o alcance de uma qualidade ambiental interior satisfatória.
Titre en anglais
Evaluation of indoor environmental quality of an artificially conditioned building, focusing on thermal comfort analysis
Mots-clés en anglais
Air conditioning
Indoor air quality
Indoor environmental quality
Sick building syndrome
Thermal comfort
Underfloor air distribution
Resumé en anglais
Occupants of artificially conditioned indoor spaces are continuously and lengthily exposed to environmental conditions mostly adverse to their activities performance and health maintenance. The purpose of this research was to evaluate some indoor air quality and thermal comfort parameters of an artificially conditioned building, and relate them to the employment of underfloor air conditioning system in spaces that differ from open-plan office spaces. Considering the studied building presents different activities on each of its floors it was necessary to choose two of them, one characterized by classrooms layout and the other by a semi open-plan office layout. The on-site data collection took place in three different steps. Step one was distinguished by three six-month cycles of air temperature, relative humidity and air velocity measurements, and fungi, particulate matter and carbon dioxide concentrations. The second step consisted of a four-day single campaign of measurements, when air temperature and relative humidity profiles were carried out, air velocity was quantified in complaining areas, and the Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) thermal comfort indexes were determined. During the third and last step, indoor environmental quality questionnaire surveys were distributed to the occupants of both studied floors. Data analysis and assessment originated from the cycles identified exceeding fungi and carbon dioxide concentrations. Temperature profiles indicated their prevalence below the recommended range. PMV and PPD indexes determination pointed to a scenery of best thermal environmental conditions for the researched spaces, with an operative temperature of 24 Celsius degrees. The results of the questionnaire surveys supported the air temperature measurements, showing supremacy of cold related thermal sensations among the occupants, especially those of female gender. It was evident that the thermal comfort of the studied environments is a disturbing factor for the activities practiced on both floors. There was a great number of occupants reporting Sick Building Syndrome (SBS) typical symptoms, what suggested actions related to indoor environmental quality should be taken in order to provide the desired health, welfare and productivity for the building occupants. It was conclusive that the operation and maintenance of underfloor air conditioned systems in indoor environments unlike open-plan offices are more complex and therefore make it harder to reach an acceptable indoor environmental quality.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-02-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.