Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2014.tde-01092014-092813
Document
Author
Full name
Carolina Gil Garcia
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2014
Supervisor
Committee
Marra Junior, Wiclef Dymurgo (President)
Aguiar, Mônica Lopes
Zaiat, Marcelo
Title in Portuguese
Montagem e operação de unidade de adsorção em leito fixo para remoção de H2S de corrente gasosa
Keywords in Portuguese
Adsorção
Curvas de efluência
Iodo
Sulfeto de hidrogênio
Abstract in Portuguese
O H2S é um gás que causa preocupação devido aos efeitos que pode provocar a saúde, a corrosão sobre alguns materiais e a redução do poder calorífero no aproveitamento de biogás, mesmo quando presente em baixas concentrações. O uso de biogás como fonte energética tem crescido nos últimos anos, impulsionando a remoção do sulfeto de hidrogênio, uma vez que a presença de tal gás reduz a capacidade calorífica do biogás e causa danos às instalações. Diante disso, várias técnicas são utilizadas na remoção de H2S, sendo uma delas, a adsorção. Os processos de separação por adsorção são muito utilizados para a remoção de poluentes gasosos de misturas gasosas. Neste trabalho foram realizados experimentos da adsorção do H2S sobre lodo seco, em coluna de leito fixo, para obtenção da capacidade de adsorção dinâmica do lodo e como esta seria afetada pelas variáveis de processo: concentração de alimentação e vazão de alimentação. Para tanto, foi concebida e instalada uma unidade de bancada de adsorção em leito fixo, com facilidades experimentais necessárias para testes dinâmicos, com o emprego da técnica de interpretação de curvas de efluência, um método útil para a avaliação do desempenho de um adsorvente em colunas de leito fixo. Testes preliminares mostraram que a unidade de bancada apresentou versatilidade, podendo ser operada com vazões de até 5 L/ min e concentração de H2S na mistura gasosa de até 500 ppm. Os resultados obtidos mostraram que a capacidade de adsorção do lodo seco foi muito baixa, com valores variando de 3,30 x 10-5 a 2,54 x 10-3 mg de H2S/g de lodo seco e existência de caminhos preferenciais no leito.
Title in English
Assembly and operation of the adsorption unit to a fixed bed to remove H2S from the gas stream
Keywords in English
Adsorption
Breakthrough curves
Hydrogen sulphide
Sludge sewage
Abstract in English
It is widely known that H2S is a gas which causes preoccupation due to the potential risks to health, corrosion in materials and reduction of the calorific value, even when present in low concentrations. The application of biogas as an energetic source has increased in last years, promoting the hydrogen sulphide removal, so that H2S presence can reduce the biogas energetic capacity and cause damage in the installations. Therefore, many techniques are used to H2S removal, one them is adsorption. The adsorption separation processes are widely used in the removal of pollutants gaseous from gas mixtures. In this work, experiments were performed on the adsorption of H2S the dry sludge in a fixed bed column, aiming to obtain the dynamic adsorption capacity and how this would be affected by the process variables: feed concentration and feed flow rate . For that, we designed and installed a bench unit to fixed bed adsorption with necessary experimental facilities for dynamic tests with the use of the technique of interpretation breakthrough curves, an useful method for evaluating the performance of an adsorbent columns fixed bed . Preliminary tests showed that the bench unit has presented versatility and efficiency and it can be operated at flow rates up to 5 L/min and H2S concentration in the gas mixture up to 500 ppm. The results showed that the adsorption capacity of the dried sludge was very low , with values varied from 3.30 × 10-5 to 2.54 × 10-3 mg H2S/g of dry sludge and the existence of preferential paths in the bed .
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
carolina_garcia.pdf (2.08 Mbytes)
Publishing Date
2014-09-02
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.