• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2006.tde-26102015-090930
Document
Author
Full name
Daniela Cristina Rebolho
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2006
Supervisor
Committee
Belo, Eduardo Morgado (President)
Goes, Luiz Carlos Sandoval
Marques, Flávio Donizeti
Pereira, João Antonio
Tsunaki, Roberto Hideaki
Title in Portuguese
Um método para identificação de parâmetros modais em tempo real
Keywords in Portuguese
Análise modal
EERA
Flutter
Identificação em tempo real
Abstract in Portuguese
Na Indústria Aeronáutica, é de extrema importância a qualidade e o desempenho de seus produtos, que estão diretamente relacionados ao projeto e ao desenvolvimento de estruturas adequadas, pois além de seu caráter funcional deve-se também garantir a sua integridade nas mais diversas condições de operação. O comportamento dinâmico destas estruturas é um dos seus principais aspectos, principalmente devido à demanda contínua para estruturas mais leves e consequentemente mais flexíveis. Tradicionalmente, as estruturas aeroespaciais devem ser submetidas a alguma forma de verificação antes do voo, de forma a assegurar que a aeronave esteja livre de qualquer fenômeno de instabilidade aeroelástica, que pode ocorrer provocando problemas de fadiga ou falhas estruturais. Um dos fenômenos de instabilidade mais importantes é denominado flutter. As técnicas de ensaio em voo para identificação de flutter são de extrema importância para o conhecimento dos limites de voo seguro. Um dos elementos essenciais para a realização de ensaios de flutter em voo é o processo de identificação dos parâmetros modais estruturais da aeronave sob teste. A identificação precisa e rápida dos parâmetros modais permite determinar com antecedência e segurança as condições de voo em que o fenômeno de flutter irá ocorrer. Atualmente as pesquisas nesta área apontam na direção do desenvolvimento de tecnologia que permita a identificação em tempo real dos parâmetros modais associados ao flutter. Neste trabalho foi realizado o estudo de um método de identificação de parâmetros modais para ser aplicado em tempo real. O método de identificação utilizado para este estudo é o EERA - Extended Eigensystem Realization Algorithm, um método de identificação no domínio do tempo considerado eficiente e poderoso, pois é capaz de identificar o comportamento dinâmico complexo em estruturas. O algoritmo foi validado através de um ensaio experimental num modelo de asa no túnel de vento, onde foram determinados os parâmetros modais envolvidos no flutter. Também foi realizado um ensaio experimental numa placa de alumínio, onde foram identificados os seus parâmetros modais, frequências naturais e fatores de amortecimento. Após sua validação, o método EERA foi adaptado e programado no equipamento de aquisição e processamento de sinais dSPACE®, que é destinado a realizar identificação em tempo real. Por último foi realizado um ensaio experimental em tempo real na placa de alumínio utilizada anteriormente, onde os parâmetros modais identificados on-line foram comparados com os identificados off-line, comprovando assim a eficiência do método na identificação em tempo real.
Title in English
A method for modal parameters identification in real time
Keywords in English
EERA
Flutter
Modal analysis
Real time identification
Abstract in English
In the Aeronautical Industry, the quality and the performance of its products, that are directly related to the project and the development of adequate structures, are of extreme importance, since, beyond their functional characteristics, their integrity, in the most diverse operation conditions, must also be guaranteed. The dynamic behavior of these structures is one of its main aspects, mainly due to continuous demand for lighter and consequently more flexible structures. Traditionally, the aerospace structures must be submitted to some form of verification before the flight, to assure that the aircraft is free of any aeroelastic instability phenomenon, which when occurring will provoke structural fatigue problems or failure. One of the more important instability phenomena is called flutter. The techniques of flight test for identification of flutter are of extreme importance for the knowledge of the limits of safe flight. One of the essential elements for the accomplishment of flutter tests in flight is the process of identification of the structural modal parameters of the aircraft under test. The accurate and fast identification of the modal parameters allows determining, with antecedence and security, the flight conditions where the phenomenon of flutter will occur. Currently the research in this area points in the direction of developing the technology that allows the identification in real time of the modal parameters associated to flutter. In this work the study of a method of identification of modal parameters was carried through to be applied in real time. The method of identification used for this study is the EERA - Extended Eigensystem Realization Algorithm, a method of identification in the time domain considered efficient and powerful, since it is capable to identifying complex dynamic behavior in structures. The algorithm was validated with an experimental test in a model of wing in the wind tunnel, where the involved modal parameters in flutter had been determined. Also an experimental test was carried out with an aluminum plate, where its modal parameters, natural frequencies and damping factors, had been identified. After its validation, the method EERA was adapted and programmed in the dSPACE® signals acquisition and processing equipment, which is used for carrying out identification in real time. Finally an experimental test, in real time, with the previously used aluminum plate was carried out, when the modal parameters identified on-line were compared with those identified off-line, thus proving the efficiency of the method for identification in real time.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-10-26
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.