• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2009.tde-15122009-112118
Documento
Autor
Nombre completo
Joaquim Eduardo Mota
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
El Debs, Mounir Khalil (Presidente)
Corrêa, Márcio Roberto Silva
França, Ricardo Leopoldo e Silva
Loriggio, Daniel Domingues
Malite, Maximiliano
Título en portugués
Contribuição ao projeto de estruturas multi-piso reticuladas em concreto pré-moldado
Palabras clave en portugués
Análise não-linear
Concreto pré-moldado
Efeitos dependentes do tempo
Estruturas multi-piso
Ligações semi-rígidas
Processo de montagem
Resumen en portugués
Estruturas em concreto pré-moldado vêm sendo utilizadas com freqüência em sistemas reticulados do tipo multi-piso, destinados às mais variadas atividades como: estabelecimentos comerciais, estacionamentos, escolas, hospitais e etc. A utilização de ligações viga-pilar do tipo semi-rígida constitui uma alternativa interessante para o enrijecimento e para a garantia da estabilidade global deste tipo de estrutura. Atualmente, a rigidez e a resistência destas ligações têm sido determinadas por ensaios de modelos em escala real. Estes ensaios, além de apresentarem um custo elevado, têm aplicação restrita à ligação examinada o que torna esta metodologia limitada e não adequada à prática de elaboração de projeto. Apresenta-se, neste trabalho, um modelo mecânico para determinação numérica da relação força-deslocamento de uma ligação viga-pilar semi-rígida a partir da contribuição da rigidez individual de cada componente de transferência de força utilizado na vinculação. A formulação do equilíbrio do modelo é implementada em planilha eletrônica constituindo-se numa ferramenta de cálculo para o projetista, permitindo o estudo, de forma rápida e amigável, da influência do posicionamento e da rigidez individual de cada componente de transferência de força na rigidez e na resistência da ligação. Este modelo mecânico foi utilizado para o cálculo da rigidez à rotação para momento fletor positivo de uma ligação viga-pilar ensaiada em laboratório. Os valores para a rigidez da ligação obtidos em ensaio e pelo modelo mecânico ficaram muito próximos. Da formulação do equilíbrio do modelo mecânico pode-se extrair ainda uma matriz de rigidez que é utilizada na representação da ligação semi-rígida no modelo de barra da estrutura. Um programa computacional foi desenvolvido para a análise de pórticos planos com ligação viga-pilar semi-rígida considerando ainda as não linearidades físicas e geométricas do modelo de cálculo. O programa foi validado pela comparação de resultados de exemplos também processados no programa ANSYS. A não-linearidade geométrica é considerada pelo método modal, não incremental-iterativo, e que obtém a parcela não-linear da resposta estrutural pela combinação dos seus modos de flambagem. A não-linearidade física do concreto é considerada pelo método da rigidez secante no qual a rigidez de cada barra da estrutura é reduzida na análise conforme suas armaduras e o nível de sua solicitação. Para o cálculo da rigidez secante dos pilares desenvolveu-se um programa que permite a consideração de armaduras ativas e passivas na seção. A análise de alguns exemplos revelou que a protensão dos pilares é também uma alternativa interessante para o enrijecimento da estrutura. Além de exemplos práticos, outros temas pertinentes ao projeto deste tipo de estrutura como: estabilidade na fase construtiva, esforços finais após a montagem, efeitos dependentes do tempo, assimetria de rigidez e plastificação das ligações, são também abordados no trabalho.
Título en inglés
Contribution to the design of precast concrete multi-storey structures
Palabras clave en inglés
Erection process
Multi-storey buildings
Nonlinear analysis
Precast concrete
Semi-rigid connection
Time-dependent effects
Resumen en inglés
Precast concrete multi-storey structures have been more frequently used to construct commercial buildings, parking, schools and hospitals. The use of semi-rigid beam-tocolumn connections is a good strategy to guarantee the global stability of this type of structure. Actually the rigidity and the strength of this type of connection are obtained in an experimental program using full scale prototypes. This procedure is not only expensive but limited and not adequate for design since the results are only valid for the examined connection. This research presents a mechanical model used to determine numerically the force-displacement relationship of a beam-to-column semirigid connection. The procedure uses the contribution of any individual force transfer component active in the connection. The equilibrium equation of the model is implemented in an electronic-worksheet where the designer can rapidly and friendly study the influence of the position and the individual rigidity of each force transfer component in the global rigidity and strength of the connection. For validation, this procedure was used to calculate the flexural rigidity for positive bending moment of a beam-to-column semi-rigid connection that was tested in laboratory. The numerical values of the connection rigidity obtained by test and by the mechanical model are very close. The matrix used in the formulation of the mechanical model equilibrium can also be used to represent the semi-rigid connection in the finite element model of the structure. A computational program was developed for plane frame analysis including semi-rigid beam-to-column connections and both physical and geometric nonlinearities. The program was tested by comparing the results of some examples that are also analysed in the ANSYS program. The geometric nonlinearity is considered by a modal method where the nonlinear response of the structure is obtained by a combination of its buckling modes. The physical nonlinearity of the concrete is considered by the secant rigidity method. In this method the rigidities of all concrete bars in the structure are reduced by coefficients that depend of the reinforcement in the cross section and the level of the efforts. A special computational program was developed to calculate the secant rigidity for a concrete cross section with reinforcing bar and prestressing steel. The analysis of some examples shows that the use of prestressing steel in collums is also an interesting alternative to sttifen the structure. Beyond of some practical examples, others themes related to the design of this type of structure like: stability in the erection process, efforts in the end of the erection process, time-dependent effects, non symmetrical and plastic behavior of the connections, are also treated in this work.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.