Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2016.tde-19022016-151911
Document
Auteur
Nom complet
Ricardo Toshiyuki Irita
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2003
Directeur
Jury
Slaets, Annie France Frère (Président)
Furuie, Sérgio Shiguemi
Infantosi, Antonio Fernando Catelli
Moraes, José Carlos Teixeira de Barros
Silva Filho, Antonio Carlos Roque da
Titre en portugais
Técnica de colimação para otimizar a aquisição e o processamento de imagens mamográficas
Mots-clés en portugais
Espalhamento
Modelagem
Quantificação da radiação X
Raios-X
Simulação da radiação X
Slit mamográfico modificado
Resumé en portugais
Para melhorar a visualização das pequenas estruturas anatômicas importantes para o diagnóstico do câncer de mama e otimizar o processamento das mamografias pelos sistemas computadorizados de auxílio ao diagnóstico (CAD), foi desenvolvido um dispositivo, baseado na tecnologia slit, que melhora a aquisição dos mamogramas. Este dispositivo reduz a radiação espalhada e o tamanho do foco e foi projetado a partir de um modelo computacional. O modelo adotado permite quantificar o valor desses parâmetros para qualquer sistema radiológico, qualquer espessura de tecidos moles radiografada e qualquer tensão aplicada ao tubo de raios-X. O dispositivo foi implementado e testado, quantificando as melhorias obtidas. As imagens geradas foram comparadas com as fornecidas pelos sistemas mamográficos convencionais. O modelo serviu para estudar também a interferência do espalhamento sobre o desempenho dos algoritmos usados nos sistemas de diagnóstico auxiliado por computador (CAD).
Titre en anglais
Collimation techniques for optimization of mammography image acquisition and processing
Mots-clés en anglais
Computer modeling
Modified mammography slit
Scatter radiation
X-ray
X-ray quantification
X-ray simulation
Resumé en anglais
In order to improve the visualization of the small and important anatomical structures for breast cancer diagnosis and to optimize the image processing of mammograms by the computer aided diagnosis systems (CAD), a device that comes from slit technology was developed to improve the acquisition of mammograms. This device reduces the amount of scattered radiation and the focus size and it can be projected from a computational model. This model allows quantifying the value of those parameters, scattered radiation and the focus size, for any radiological system, any X-rayed soft tissue thickness and any tension applied to the X-ray tube. The device was implemented and tested quantifying the obtained improvements. The generated images were compared to the supplied for conventional mammography systems. The model was also good for studying interference on the algorithms used in the computer aided diagnosis systems (CAD).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-02-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.