Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2016.tde-19022016-151911
Documento
Autor
Nombre completo
Ricardo Toshiyuki Irita
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2003
Director
Tribunal
Slaets, Annie France Frère (Presidente)
Furuie, Sérgio Shiguemi
Infantosi, Antonio Fernando Catelli
Moraes, José Carlos Teixeira de Barros
Silva Filho, Antonio Carlos Roque da
Título en portugués
Técnica de colimação para otimizar a aquisição e o processamento de imagens mamográficas
Palabras clave en portugués
Espalhamento
Modelagem
Quantificação da radiação X
Raios-X
Simulação da radiação X
Slit mamográfico modificado
Resumen en portugués
Para melhorar a visualização das pequenas estruturas anatômicas importantes para o diagnóstico do câncer de mama e otimizar o processamento das mamografias pelos sistemas computadorizados de auxílio ao diagnóstico (CAD), foi desenvolvido um dispositivo, baseado na tecnologia slit, que melhora a aquisição dos mamogramas. Este dispositivo reduz a radiação espalhada e o tamanho do foco e foi projetado a partir de um modelo computacional. O modelo adotado permite quantificar o valor desses parâmetros para qualquer sistema radiológico, qualquer espessura de tecidos moles radiografada e qualquer tensão aplicada ao tubo de raios-X. O dispositivo foi implementado e testado, quantificando as melhorias obtidas. As imagens geradas foram comparadas com as fornecidas pelos sistemas mamográficos convencionais. O modelo serviu para estudar também a interferência do espalhamento sobre o desempenho dos algoritmos usados nos sistemas de diagnóstico auxiliado por computador (CAD).
Título en inglés
Collimation techniques for optimization of mammography image acquisition and processing
Palabras clave en inglés
Computer modeling
Modified mammography slit
Scatter radiation
X-ray
X-ray quantification
X-ray simulation
Resumen en inglés
In order to improve the visualization of the small and important anatomical structures for breast cancer diagnosis and to optimize the image processing of mammograms by the computer aided diagnosis systems (CAD), a device that comes from slit technology was developed to improve the acquisition of mammograms. This device reduces the amount of scattered radiation and the focus size and it can be projected from a computational model. This model allows quantifying the value of those parameters, scattered radiation and the focus size, for any radiological system, any X-rayed soft tissue thickness and any tension applied to the X-ray tube. The device was implemented and tested quantifying the obtained improvements. The generated images were compared to the supplied for conventional mammography systems. The model was also good for studying interference on the algorithms used in the computer aided diagnosis systems (CAD).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.