• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.11.2016.tde-19042016-103353
Document
Auteur
Nom complet
Acácio Perboni
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2015
Directeur
Jury
Frizzone, Jose Antonio (Président)
Botrel, Tarlei Arriel
Camargo, Antonio Pires de
Pinto, Marinaldo Ferreira
Teixeira, Marconi Batista
Titre en portugais
Sensibilidade de gotejadores à obstrução por partículas de areia
Mots-clés en portugais
Concentração
Granulometria
Microirrigação
Partículas sólidas inertes
Resumé en portugais
Os fatores envolvidos na obstrução dos gotejadores são divididos em químicos, físicos e biológicos, os quais, dependem da qualidade da água utilizada na irrigação e dos adubos utilizados em fertirrigação. Dentre os fatores físicos estão as partículas de areia, que são classificadas como sólidas inertes, pois não sofrem agregação com outras partículas já presentes na água e nem dispersão. O objetivo deste trabalho foi avaliar a influência do tamanho e concentração de partículas de areia e da velocidade de escoamento da água nas linhas laterais na obstrução de um único modelo de gotejador do tipo cilíndrico, não regulado, com vazão nominal de 2 L h-1. Foram realizados ensaios de obstrução com areia misturada em água destilada, combinando os seguintes fatores: três faixas granulométricas de partículas de areia (53-105; 105-250 e 250-500 μm), três concentrações de areia na água destilada (100, 250 e 500 mg L-1) e três velocidades de escoamento da água no início das linhas laterais (0,13; 0,25 e 0,94 m s-1). O tempo de ensaio para cada combinação de fatores foi de 48 horas. A vazão de 32 gotejadores foi medida a cada doze minutos por meio de um sistema automatizado desenvolvido durante esta pesquisa, sendo que esse operou adequadamente durante todo o período de ensaios de obstrução. Utilizaram-se oito linhas laterais conectadas em linha de derivação com bifurcações simétricas, cuja finalidade era distribuir uniformemente a água as partículas de areia entre as linhas laterais. Em ensaios com faixa granulométrica de 105 a 250 μm, ocorreu a obstrução nas concentrações de 250 e 500 mg L-1, para as velocidades de escoamento da água no inicío das linhas laterais V2 (0,25 m s-1) e V3 (0,94 m s-1). Já na faixa granulométrica de 250 a 500 μm, ocorreu obstrução nas concentrações de 100, 250 e 500 mg L-1, para V2 e V3. A obstrução de gotejadores ocorreu de forma aleatória nas oito linhas laterais. Após obstruídos os gotejadores não desobstruíram com o passar do tempo de ensaio, portanto fenômenos de autolimpeza não foram observados durante os experimentos.
Titre en anglais
Sensitivity of drippers to clogging caused by sand particles
Mots-clés en anglais
concentration
inert solid particles
Micro irrigation
particle size
Resumé en anglais
Clogging of emitters is influenced by chemical, physical and biological agents that are associated with irrigation water quality and fertilizers, in case of adoption of fertigation practices. Among the physical agents, sand particles are one of the most important clogging sources. Sand particles are considered to be inert since it does not aggregate with other particles suspended in water. The purpose of this research was to assess influence of concentration, size of sand particles, and flow velocity within laterals on sensitivity of drippers to clogging. The results are limited to a cylindrical integrated dripper of 2 L h-1 nominal flow rate that is a nonpressure compensating emitter. Experiments were undertaken using distilled water and sand particles. The following levels were evaluated: (a) three ranges of particles sizes (0.053-0.105; 0.105-0.25 and 0.25-0.5 mm); (b) three concentrations of particles (100, 250 and 500 mg L-1); and, (c) three flow velocities at the laterals inlet (0.13, 0.25 and 0.94 m s-1). Each testing level had 48 hours duration. The flow rate of 32 drippers was measured every 12 minutes by an automated system developed and successfully validated during this research. A manifold with symmetrical bifurcations was designed to assure uniform water distribution among eight parallel laterals installed on the testing bench. Within the range of particle sizes from 105 to 250 μm, clogging of emitters was observed under concentration of particles of 250 and 500 mg L-1 and under flow velocities of 0.25 and 0.94 m s-1. Within the range of particles sizes from 250 to 500 μm, clogging was observed under all concentrations and under flow velocities of 0.25 and 0.94 m s-1. Apparently, clogging of emitters of the eight laterals occurred randomly. Once clogged, emitters did not recovered its initial flow rate, therefore self-cleaning phenomena was not observed during the experiments.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-05-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.