• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.11.2009.tde-10092009-081324
Document
Author
Full name
Mariana Ventura Martins
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2009
Supervisor
Committee
Libardi, Paulo Leonel (President)
Alves, Marlene Cristina
Silva, Alvaro Pires da
Title in Portuguese
Influência da distância de instalação de tensiômetros no campo para o cálculo do gradiente de potencial total no método do perfil instantâneo
Keywords in Portuguese
Água do solo
Condutividade hidráulica do solo - Determinação - Métodos.
Abstract in Portuguese
Para determinar a condutividade hidráulica do solo em condições de não saturação, o método mais utilizado para estimativas no campo tem sido o do perfil instantâneo. Este método baseia-se na integração da equação de Richards em relação à profundidade do solo, durante o processo de redistribuição da água, após a saturação do perfil até a profundidade de interesse e prevenção do fluxo de água pela superfície do solo. A equação resultante para a aplicação do método exige o conhecimento do gradiente de potencial total na profundidade de interesse, durante o processo de redistribuição. A hipótese básica do trabalho é a de que há uma distância correta entre as cápsulas do tensiômetro, para o cálculo do gradiente de potencial total, na aplicação do método do perfil instantâneo, que confere menor erro à determinação da condutividade hidráulica. Em dois solos com texturas bem diferentes foi instalada uma estrutura metálica retangular de 4,50 m de comprimento, 3,00 m de largura e 0,60 m de altura (0,40 m no solo), no centro da qual foram instalados 26 tensiômetros com manômetro de mercúrio a cada 25 mm, desde 0,10 até 0,60 m de profundidade, para o cálculo do gradiente de potencial total na profundidade de 0,50 m. O gradiente de potencial total utilizado como referência foi calculado pela derivada de equação de ajuste do potencial total com a profundidade do solo; os demais gradientes foram calculados pelo método das diferenças finitas utilizando, para o comprimento do solo (distância entre as cápsulas), os valores 0,05, 0,10, 0,15 e 0,20 m. Destes valores somente a distância 0,05 m resultou em gradientes diferentes em relação à referência para os dois solos testados, com o que pode-se recomendar os demais comprimentos para o cálculo do gradiente de potencial total no método do perfil instantâneo. Também pode-se concluir que para o solo arenoso a hipótese do gradiente unitário não se adequou corretamente aos dados, subestimando em até 75% o valor da condutividade hidráulica.
Title in English
Influence of the distance of installation of tensiometers to calculate total potential gradient in the field soil hydraulic conductivity determination
Keywords in English
Soil hydraulic conductivity-Determination-Methods.
Soil water
Abstract in English
The soil hydraulic conductivity determination method most used under unsaturated field conditions is the instantaneous profile method. This method is based on the integration of Richards equation in relation to soil depth, during the soil water redistribution process, after the profile has been saturated till the interest depth and the soil surface prevented to water flux. The equation that results from the method requires the knowledge of the total potential gradient at the interest depth during the redistribution depth. The basic hypothesis of this work is that there is an installation correct distance of the tensiometer porous cups to calculate the total potential gradient in the instantaneous profile method that provides less error to the hydraulic conductivity determination. In two very distinct texture soil. A metallical rectangular structure of 4.50 m length, 3.00 m width and 0.60 m depth was installed into the soil profile, leaving 0.20 m of its depth above the soil surface. In the center of the delimited area, 26 mercury tensiometers were installed at each 25 mm along the profile from soil depth of 0.10 m to 0.60 m, to calculate the total potential gradient at the 0.50 m soil depth. The gradient used as reference was that calculated by differentiation of the fitted curve of total potential as a function of the vertical position coordinate for the depth of 0.50 m; the other gradients were calculated by finite differences using the distances of 0.05, 0.10, 0.15 and 0.20 m between installed porous cups. Among these values, only the distance of 0.05 m resulted in gradients different of the reference for both soils. Therefore, the other distances (0.10, 0.15 and 0.20 m) away be recommended to calculated the soil water total potential by finite differences in the instantaneous profile method. Would be concluded that the assumption of unit gradient was not suitable for the data obtained for the sandy soil, underestimating the hydraulic conductivity by up to 75%.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Mariana_Martins.pdf (1.58 Mbytes)
Publishing Date
2009-09-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.