• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.99.2017.tde-06122017-140621
Documento
Autor
Nombre completo
Lilian Muniz Camilo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Chioccola, Vera Lucia Pereira (Presidente)
Motoie, Gabriela
Okay, Thelma Suely
Strejevitch, Cristina da Silva Meira
Título en portugués
Diagnóstico molecular da toxoplasmose sintomática: um estudo retrospectivo e prospectivo de 9 anos num laboratório de referência no Estado de São Paulo
Palabras clave en portugués
Diagnóstico
Reação em cadeia por polimerase
Toxoplasma gondii
Toxoplasmose
Resumen en portugués
As formas sintomáticas de toxoplasmose são um grave problema de saúde pública e ocorrem em cerca de 10 a 20% das pessoas infectadas. Com o objetivo de melhorar o diagnóstico molecular de toxoplasmose sintomática em pacientes brasileiros, este estudo avaliou o desempenho da PCR em tempo real (qPCR) na detecção do DNA de T. gondii testando dois conjuntos de iniciadores moleculares (B1 e REP-529) para diagnóstico molecular. A metodologia foi testada em 807 amostras clínicas com diagnóstico clínico conhecido, ELISA e PCR convencional (cPCR) em um período de 9 anos. Todas as amostras foram de pacientes com suspeita clínica de diferentes formas da toxoplasmose. De acordo com a curva mínima de limite de detecção (no CT), o REP-529 apresentou maior sensibilidade para detectar DNA de T. gondii do que B1. Ambos os conjuntos de iniciadores moleculares foram avaliados retrospectivamente usando o DNA de 515 amostras clínicas diferentes. Os 122 pacientes com resultado negativo na PCR em tempo real, provavelmente por terem infecção crônica, demonstraram alta especificidade (REP-529, 99,2% e B1, 100%). Das 393 amostras com ELISA positivo (IgG), 146 apresentaram diagnóstico clínico de toxoplasmose e cPCR positivo. As sensibilidades de REP-529 e B1 foram de 95,9% e 83,6%, respectivamente. A comparação dos desempenhos do REP-529 e B1 foi analisada prospectivamente em 292 amostras. Assim, a partir de um total de 807 amostras de DNA analisadas, 217 (26,89%) apresentaram PCR positivo, pelo menos em um conjunto de iniciadores e com toxoplasmose sintomática confirmada pelo diagnóstico clínico. O REP-529 foi positivo em 97,23%, enquanto o B1 amplificou apenas 78,80%. Depois de comparar várias amostras em um laboratório brasileiro de referência, este estudo concluiu que o conjunto de iniciadores REP-529 apresentou melhor desempenho do que B1. Essas observações foram baseadas após o uso de casos com diagnóstico clínico definido, ELISA e cPCR.
Título en inglés
Molecular diagnosis of symptomatic toxoplasmosis: a retrospective and prospective 9-year study in a reference laboratory in São Paulo State
Palabras clave en inglés
Diagnosis
Polymerase chain reaction
Toxoplasma gondii
Toxoplasmosis
Resumen en inglés
Symptomatic forms of toxoplasmosis are a serious public health problem and occur in around 10-20% of the infected people. Aiming to improve the molecular diagnosis of symptomatic toxoplasmosis in Brazilian patients, this study evaluated the performance of real time PCR (qPCR) in detecting T. gondii DNA testing two primer sets (B1 and REP-529) for molecular diagnosis. The methodology was assayed in 807 clinical samples with known clinical diagnosis, ELISA, and conventional PCR (cPCR) results in a 9-year period. All samples were from patients with clinical suspicion of several features of toxoplasmosis. According to the minimum detection limit curve (in CT), REP-529 had greater sensitivity to detect T. gondii DNA than B1. Both primer sets were retrospectively evaluated using 515 DNA from different clinical samples. The 122 patients without toxoplasmosis (with negative real-time PCR) provided high specificity (REP-529, 99.2% and B1, 100%). From the 393 samples with positive ELISA (IgG), 146 had clinical diagnosis for toxoplasmosis and positive cPCR. REP-529 and B1 sensitivities were 95.9% and 83.6%, respectively. Comparison of REP-529 and B1 performances was further analyzed prospectively in 292 samples. Thus, from a total of 807 DNA analyzed, 217 (26.89%) had positive PCR with, at least one primer set and with symptomatic toxoplasmosis confirmed by clinical diagnosis. REP-529 was positive in 97.23%, whereas B1 amplified only 78.80%. After comparing several samples in a Brazilian referral laboratory, this study concluded that REP-529 primer set had better perform than B1 one. These observations were based after using cases with defined clinical diagnosis, ELISA, and cPCR.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-12-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.