Doctoral Thesis
DOI
https://doi.org/10.11606/T.98.2019.tde-27072020-110331
Document
Author
Full name
Mário Barbosa Guedes Nunes
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2019
Supervisor
Committee
Moreira, Dalmo Antonio Ribeiro (President)
Feres, Fausto
Figueiredo, Marcio Jansen de Oliveira
Samesima, Nelson
Title in Portuguese
Desnível do segmento ST ao eletrocardiograma intracoronário como preditor de infarto periprocedimento na intervenção coronária percutânea em doença arterial coronária estável
Keywords in Portuguese
Avaliação de Risco
Doença da Artéria Coronariana
Eletrocardiografia
Infarto do Miocárdio
Intervenção Coronária Percutânea
Abstract in Portuguese
INTRODUÇÃO: Apesar do avanço nos materiais e técnicas, o infarto periprocedimento ainda é uma complicação frequente da intervenção coronária percutânea (ICP). Alterações do segmento ST em um registro eletrocardiográfico intracoronário (ECG-IC) durante a ICP, estão associadas a elevação de marcadores de injúria miocárdica após o procedimento. No entanto, não se conhece relação entre desnível do segmento ST intracoronário e a ocorrência de infarto periprocedimento. O objetivo desta pesquisa é investigar associação entre a ocorrência de desnivelamento do segmento ST ao ECG-IC durante a ICP e a ocorrência de infarto periprocedimento. MÉTODOS: Foram incluídos pacientes consecutivos, portadores de doença arterial coronária (DAC) estável, com indicação de ICP. Durante o procedimento, foram obtidos registros eletrocardiográficos intracoronários. A partir desses traçados, avaliamos correlação entre desnivelamento do segmento ST durante o procedimento e incidência de infarto periprocedimento. RESULTADOS: Foram incluídos 53 pacientes. Apenas um caso de infarto periprocedimento foi registrado. Não houve diferença significativa na incidência de elevação de troponina entre pacientes com desnível do ST intracoronário e aqueles com ST isoelétrico durante a ICP (59,4% vs. 52,4%, p=0,307). CONCLUSÃO: Em função da baixa ocorrência do desfecho primário, não se verificou correlação com alterações do segmento ST ao letrocardiograma intracoronário. Alterações dinâmicas do ST ao ECG-IC não se mostraram associadas à aumento de troponina em casos de doença arterial coronária estável, submetidos a intervenção coronária percutânea.
Title in English
Intracoronary ST-segment deviation as a predictor of periprocedural infarction after percutaneous coronary intervention in stable coronary artery disease
Keywords in English
Coronary Artery Disease
Electrocardiography
Myocardial Infarction
Percutaneous Coronary Intervention
Risk Assessment
Abstract in English
INTRODUCTION: Despite advances in materials and techniques, periprocedural infarction is still a frequent complication of percutaneous coronary intervention (PCI). Changes in ST segment on an intracoronary electrocardiographic lead (IC-ECG) during PCI are associated with greater myocardial injury markers release after the procedure. However, there is no known relationship among intracoronary ST segment deviation and incidence of periprocedural infarction. We aimed to investigate the association among intracoronary ST segment deviation and periprocedural infarction incidence. METHODS: Consecutive stable coronary artery disease (CAD) patients submitted for PCI were recruted. During the procedure, intracoronary electrocardiographic records were performed. We evaluated correlation among intracoronary ST-segment deviation and periprocedural infarction. RESULTS: Fifty three patients were included. Only one periprocedural infarction case was recorded. There was no significant difference in post-PCI troponin increase between patients with intracoronary ST elevation and those with isoelectric ST during PCI (59.4% vs. 52.4%, p = 0.307). CONCLUSION: Due to primary outcome low occurence, no correlation was found among intracoronary ST-segment deviation with periprocedural myocardial infarction in stable coronary artery disease PCI cases. Dynamic ST changes in IC-ECG were not associated with increased troponin in this population.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2020-08-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.