• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.98.2018.tde-17092018-095537
Document
Auteur
Nom complet
Tiago Costa Bignoto
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2018
Directeur
Jury
Moreira, Dalmo Antonio Ribeiro (Président)
Figueiredo, Marcio Jansen de Oliveira
Mastrocola, Luiz Eduardo
Rochitte, Carlos Eduardo
Titre en portugais
Correlação entre escore de Selvester e realce tardio na tomografia computadorizada do coração em portadores de miocardiopatia hipertrófica
Mots-clés en portugais
Cardiomiopatia Hipertrófica
Selvester QRS Cardiovascular
Técnicas de Diagnóstico
Tomografia Computadorizada Multidetectores
Resumé en portugais
A Miocardiopatia hipertrófica foi descrita há mais de 50 anos e é a cardiopatia de causa genética mais comum no mundo. Pacientes portadores de miocardiopatia hipertrófica podem apresentar maior risco de eventos arrítmicos graves e morte súbita. Assim torna-se importante o desenvolvimento de técnicas de rastreio desse subgrupo de pacientes para, quando necessário, indicar tratamento específico como o implante de CDI. O realce tardio é a manifestação de fibrose nos exames de imagem como tomografia computadorizada do coração e/ou ressonância cardíaca em pacientes com cardiopatias e quando presente em grandes quantidades, pode estar relacionado a maior incidência de eventos fatais. O eletrocardiograma é ferramenta de baixo custo, não invasiva e difundida nos serviços de saúde brasileiros. O objetivo desse estudo é avaliar a correlação entre a presença e localização de realce tardio na tomografia computadorizada do coração e o achado de fibrose pelo escore de Selvester no eletrocardiograma de repouso de portadores de MCPH, determinar a prevalência de fibrose miocárdica entre os pacientes, comparando a sensibilidade, especificidade, valor preditivo positivo e negativo do escore de Selvester. Foram analisados 112 pacientes do ambulatório de miocardiopatia do Instituto Dante Pazzanese de Cardiologia portadores de miocardiopatia hipertrófica sendo incluídos 75 desses. Foram divididos em dois grupos: Portadores de CDI com 60 pacientes e sem CDI com 15 pacientes. Foram coletados dados clínicos, ecocardiográficos, eletrocardiografia digital e tomografia computadorizada do coração. Foram realizados os cálculos do escore de Selvester e a mensuração e localização de realce tardio nos cortes tomográficos dos pacientes. A correlação dos resultados foi analisada pelo método de regressão linear. As características e frequências mais marcantes do grupo foram sexo masculino 49,4%, idade 41,63 ± 15,16, classe funcional I/II - NYHA 90,6%, fibrilação atrial 21,3%, baixa prevalência de comorbidades como hipertensão arterial 37,3%, diabetes 4%, dislipidemia 17,3%, clearence de creatinina > 60mL/min em 100% e ausência de doença coronariana estabelecida, fração de ejeção do ventrículo esquerdo preservada de 69,9 ± 5,46, medida do septo interventricular de 21,04 ± 6,23 e prevalência de gradiente > 30mmHg na via de saída do ventrículo esquerdo de 37,3%. Dos fatores de risco clássicos, morte súbita familiar e história de síncope eram as mais prevalentes com 57,3% cada, o uso do beta-bloqueador ocorreu em 89,3%. A massa de fibrose pela tomografia computadorizada foi de 9,87 ± 10,79 equivalendo a porcentagem de 5,66 ± 6,16, tendo prevalência em 88% da amostra. Já pelo escore de Selvester, encontramos 8,44 ± 7,39 de porcentagem de fibrose com prevalência de 76%. Na análise de kappa para a variável categórica fibrose entre o escore de Selvester e a tomografia computadorizada do coração, foi encontrada fraca correlação com r = 0,38 (p < 0,01). Enquanto variável contínua aplicando o método de regressão linear, foi encontrada correlação forte com r = 0,7 (p < 0,01). A sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do escore de Selvester para o diagnóstico de fibrose foram de, respectivamente, 84,8%, 88,8%, 98,2% e 44,4%. A localização da fibrose apresentou correlação fraca entre os métodos com r = 0,16 (p < 0,01). Os dados desse estudo indicam que há moderada correlação entre o escore de Selvester e o realce tardio pela tomografia computadorizada na quantificação de fibrose em pacientes portadores de miocardiopatia hipertrófica.
Titre en anglais
Correlation between Selvester QRS score and late enhancement on multidetector computed tomography in patients with hypertrophic cardiomyopathy
Mots-clés en anglais
Cardiovascular Diagnostic Techniques
Hypertrophic cardiomyopathy
Multidetector Computed Tomography
Selvester QRS score
Resumé en anglais
Hypertrophic cardiomyopathy is considered the most common genetic cardiovascular disease and has been recognized for 50 years. Patients with hypertrophic cardiomyopathy may present risk of arrhythmic events and sudden cardiac death. Thus, it is important to develop screening techniques for this subgroup of patients to indicate, when necessary, specific treatment as implantable cardioverter defibrillator. Late enhancement is fibrosis manifestation in images exam as multidetector computed tomography and/or magnetic cardiac resonance and if present in large quantities may be related to a higher incidence of fatal events. The electrocardiogram is a low-cost, non-invasive tool that is present in most Brazilian health services. The purpose of this study was to test the presence and location correlation between the Selvester and the late enhancement in the multidetector computed tomography, to determine the prevalence of myocardial fibrosis among patients, comparing the sensitivity, specificity, positive and negative predictive value of the Selvester QRS score. A total of 112 patients from the Institute of Cardiology Dante Pazzanese outpatient clinic with hypertrophic cardiomyopathy were analyzed, and 75 of them were included. They were divided into two groups: ICD patients with 60 patients and no ICD with 15 patients. Clinical, echocardiographic, digital electrocardiography and computed tomography of the heart were collected. The Selvester score was calculated and the measurement and location of late enhancement in the tomographic sections of the patients were performed. The correlation of the results was analyzed by the linear regression. The most remarkable features and frequencies of the group were male gender 49.4%, age 41.63 ± 15.16 years, functional class I / II - NYHA 90.6%, atrial fibrillation 21.3%, low prevalence of comorbidities as hypertension 37.3%, diabetes 4%, dyslipidemia 17.3%, creatinine clearance > 60mL/min in 100% and absence of known coronary artery disease, left ventricular ejection fraction preserved 69.9 ± 5.46, measured of the interventricular septum 21.04 ± 6.23 and prevalence of gradient > 30mmHg in the left ventricular outflow tract 37.3%. Classic risk factors as sudden family death and history of syncope were the most prevalent 57.3% each, the use of beta-blocker occurred in 89.3%. The mass of fibrosis by multidetector computed tomography was 9.87 ± 10.79g, representing a percentage of 5.66 ± 6.16, with a prevalence of 88% of the sample. Selvester QRS score, was found 8.44 ± 7.39 percent of fibrosis with a prevalence of 76%. In the kappa analysis for the categorical variable between the Selvester score and the computed tomography of the heart, we found a weak correlation r = 0.38 (p <0.01), as a continuous variable applying the linear regression, a strong correlation was found r = 0.7 (p <0.01). The sensitivity, specificity, positive predictive value and negative predictive value of the Selvester QRS score for the diagnosis of fibrosis were 84.8%, 88.8%, 98.2% and 44.4%, respectively. The location of the fibrosis showed weak correlation between the methods r = 0.16 (p <0.01). The results of this study indicate there is a moderate correlation between the Selvester QRS score and the late enhancement by multidetector computed tomography in the quantification of fibrosis in patients with hypertrophic cardiomyopathy.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-09-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.