Tese de Doutorado
DOI
https://doi.org/10.11606/T.98.2017.tde-04102017-104138
Documento
Autor
Nome completo
Lucas Arraes de França
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2017
Orientador
Banca examinadora
Assef, Jorge Eduardo (Presidente)
Mangione, José Armando
Moises, Valdir Ambrósio
Siqueira, Dimytri Alexandre de Alvim
Título em português
Medida do strain bidimensional do ventrículo esquerdo pré-implante percutâneo de endoprótese valvar aórtica: correlação com a evolução após o procedimento
Palavras-chave em português
strain Bidimensional
Ecocardiografia/métodos
Estenose da Valva Aórtica
Função Ventricular Esquerda
Substituição da Valva Aórtica Transcateter
Resumo em português
INTRODUÇÃO: O implante transcateter de prótese valvar aórtica (TAVI) surge nos dias atuais como uma opção terapêutica para os pacientes sintomáticos portadores de estenose aórtica grave. Cerca de 200 mil pacientes em todo o mundo já foram submetidos ao TAVI. Não há grandes estudos que tenham avaliado a correlação prognóstica entre parâmetros ecocardiográficos antes do TAVI e eventos cardiovasculares a longo prazo. É relevante analisar se o strain pré-procedimento e outros parâmetros se comportam como fatores preditores independentes de eventos após o procedimento. MÉTODOS: Foram avaliados, de novembro de 2009 a outubro de 2016, 86 pacientes, submetidos a avaliação ecocardiográfica antes do TAVI e 30 dias após o procedimento, com análise do strain do ventrículo esquerdo pelo speckle tracking bidimensional e outros parâmetros ecocardiográficos. Esses pacientes foram acompanhados clinicamente e avaliados quanto aos desfechos: mortalidade global, mortalidade cardiovascular, classe funcional de insuficiência cardíaca e necessidade de reinternação cardiovascular. RESULTADOS: O strain global longitudinal pré-TAVI reduzido (valor absoluto) aumentou a chance de reinternação cardiovascular (OR: 0,87; 0,77 ±0,99; P= 0,038). A redução da relação E/e´ em 30 dias após o TAVI associou-se à queda da mortalidade global (OR: 0,97; 0,95 ±0,99; P = 0,006), bem como valores elevados pré procedimento dessa relação se associaram a maiores taxas de insuficiência cardíaca classe funcional III ou IV da New York Heart Association após a intervenção (OR: 1,08; 1±1,18; P = 0,049). CONCLUSÃO: Os resultados deste trabalho indicam que o strain global longitudinal pré-procedimento demonstrou ser um preditor de reinternação cardiovascular pós-intervenção a longo prazo. A relação E/e´ pré-procedimento apresentou correlação diretamente proporcional com o desenvolvimento de insuficiência cardíaca classe funcional III ou IV a longo prazo, assim como sua queda acentuada 30 dias após o procedimento correlacionou-se com menor mortalidade global.
Título em inglês
Measurement of bidimensional strain of left ventricle before percutaneous implantation of aortic valve endoprosthesis: correlation with evolution after the procedure
Palavras-chave em inglês
Aortic Valve Stenosis
Echocardiography
Left Ventricular Function
strain
Transcatheter Aortic Valve Replacement
Resumo em inglês
INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a therapeutic option for symptomatic patients with severe aortic stenosis. Approximately 200,000 patients around the world have already undergone TAVR. No large studies have evaluated prognostic correlation between echocardiographic parameters before TAVR and long-term cardiovascular events. It is relevant to analyze strain before procedure and how other parameters work as independent predictors of events after the procedure. METHODS: A total of 86 patients were evaluated from November 2009 to October 2016. They underwent echocardiographic evaluation before TAVR and 30 days after the procedure with analysis of strain of the left ventricle by bidimensional speckle tracking and other echocardiographic parameters. Patients were followed clinically and evaluated in relation to outcomes: global mortality, cardiovascular mortality, functional class of heart failure and need for cardiovascular readmissions. RESULTS: Global longitudinal strain before reduced TAVR (absolute value) increased the chance of cardiovascular readmission (odds ratio: 0.87; 0.77 ± 0.99; p = 0.038). Reduction of E/e´ relationship 30 days after TAVI was associated with a drop in global mortality (odds ratio: 0.97; 0.95 ± 0.99; p = 0.006). In addition, high values for this relation before the procedure were associated with higher rates of New York Heart Association functional class III or IV heart failure after the intervention (odds ratio: 1.08; 1.00 ± 1.18; p = 0.049). CONCLUSIONS: Results of this study indicate that global longitudinal strain before the procedure is a predictor of cardiovascular readmission after TAVR. The E/e´relationship before the procedure presented a correlation directly proportional to the development of long-term functional class III or IV heart failure as well as its accentuated drop 30 days after the procedure was correlated with lower global mortality.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2017-10-19
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.