Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.97.2008.tde-22082013-104314
Document
Auteur
Nom complet
Wolney de Jesus Jardim
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Lorena, 2008
Directeur
Jury
Silva, Maria Lúcia Caetano Pinto da (Président)
Correa, Sergio Machado
Giordani, Domingos Savio
Titre en portugais
Construção e avaliação de eletrodos de Nióbio/Óxido de Nióbio para determinações potenciométricas
Mots-clés en portugais
Eletrodo
Nióbio/Óxido de Nióbio
Potenciometria
Resumé en portugais
A construção de sensor potenciométrico, utilizando Nióbio acoplado a eletrodo de referência de prata/cloreto de prata num mesmo instrumento, possibilita o acompanhamento da variação de potencial que ocorre durante uma reação ácido-base em meio aquoso. Foi utilizado eletrodo de vidro combinado, cuja membrana de vidro foi danificada fisicamente, porém com sua referência interna em pleno funcionamento. O eletrodo de Nióbio foi confeccionado com metal polido ou então com a superfície modificada com óxido eletrodepositado. O crescimento de óxido sobre o Nióbio foi obtido por eletrólise em meio a H3PO4 diluído. O metal ou o par metal/óxido foi fixado no eletrodo de vidro contendo uma solução eletrolítica. O eletrodo de Nióbio não apresenta boa sensibilidade quando utilizado como indicador em potenciometria direta, mas é sensível às variações de potenciais que ocorrem em titulações ácido-base. O eletrodo de Nióbio metálico pode substituir o eletrodo de vidro combinado na determinação do teor de acidez de vinagres.
Titre en anglais
Construction and evalution of Niobium/Niobium Oxide electrodes for potentiometric determination
Mots-clés en anglais
Electrode
Niobium/Niobium Oxide
Potentiometry
Resumé en anglais
The construction of potentiometric sensors, using Niobium combined with the reference electrode silver / silver chloride in a single instrument, allows the variation of potential monitoring that occurs during an acid-base reaction in aqueous media. It was used a combined electrode glass, whose glass membrane was damaged physically, but with the internal reference in full operation. The Niobium electrode was made with polished metal or with the surface modified by electrodeposited oxide. The oxide growth was obtained by electrolysis in the H3PO4 diluted media. The metal or metal/oxide was fixed in glass electrode containing a electrolyte solution. The Niobium electrode doesn't show sensitivity when used as an indicator in direct potentiometry, but is sensitive to changes of potential that occur in acid-base titrations. The electrode of Niobium metal can replace the glass electrode combined in determining the level of acidity of vinegar.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.