• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2015.tde-17062015-150742
Document
Auteur
Nom complet
Antonio Marcos Callejo de Souza
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Prado, María Segunda Aurora (Président)
Galdos, Angel Arturo Gaona
Lourenço, Felipe Rebello
Titre en portugais
Métodos eletroforéticos e cromatográficos aplicados para a determinação simultânea de fármacos hipolipidêmicos em medicamentos
Mots-clés en portugais
Cromatografia eletrocinética micelar
Ezetimiba
HPLC
Sinvastatina
Validação analítica
Resumé en portugais
A ezetimiba e a sinvastatina são fármacos hipolipidêmicos. A ezetimiba pertence à nova classe das 2 - azetidinona, inibidores e bloqueadores do colesterol intestinal. A sinvastatina pertence à classe dos inibidores competitivos da hidroxi-3-metilglutarilcoenzima A redutase (HMG-CoA), que é a última etapa regulada na síntese do colesterol. O objetivo do trabalho foi desenvolver e validar métodos por cromatografia liquida de alta eficiência (HPLC) e eletroforese capilar (CE), rápidos, seletivos e confiáveis para determinação dos hipolipidêmicos em formulações farmacêuticas. A separação cromatográfica foi realizada usando coluna Nano separation technologies (NST) Cianopropril (CN) (150 mmx 4,6 mm, com partícula 3,5 µm), e eluição isocrático usando água purificada: acetonitrila (48:52, v/v); vazão 0,8 mL/min e volume de injeção de 20 µL. A temperatura da coluna foi de 35 ºC e a detecção foi realizada com detector na região do UV em 238 nm. O método por cromatografia eletrocinética micelar (MEKC) foi desenvolvido utilizando capilar de sílica fundida 30 cm (comprimento efetivo) x 50 µm d.i. e eletrólito constituído de tetraborato de sódio (TBS) 20 mmol L-1: dodecil sulfato de sódio (SDS) 30 mmol L-1, pH 9,0 ajustado com 10% ácido fosfórico: acetonitrila 12% v/v. O tempo de injeção foi de 3 segundos com pressão hidrodinâmica de 20 mbar, voltagem aplicada de 30 kV e detecção no UV em 238 nm. Os métodos analíticos foram validados de acordo com os requerimentos vigentes da ANVISA, ICH e Farmacopéia Americana. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e adequados para quantificação simultânea da ezetimiba e sinvastatina em formas farmacêuticas sólidas.
Titre en anglais
Electrophoretic and chromatographic methods apllied for the simultaneous determination of hypolipidemic drugs in medicines.
Mots-clés en anglais
Analytical validation
Ezetimbe
HPLC
Micellar electrokinetic chromatography
Simvastatin
Resumé en anglais
Ezetimibe and simvastatin are hipolipidemic drugs. Ezetimibe belongs to a new class of 2 - azetidione, inhibitors and blockers of intestinal chrolesterol. Simvastatin belongs a class of competitive inhibitors of 3-hydroxymethylglutaryl-coenzyme A (HMG-CoA) reductase, which is the last regulated step in the cholesterol synthesis. The aim of this project was to develop and validate fast, selective and reliable chromatographic and electrophoretic methods, to determine hypolipidemic drugs in pharmaceutical formulations. The chromatographic separation was carried out on a Nano separation technologies (NST) Cyanpropyl (CN) (150 mm x 4,6 mm, 3,5 µm), isocratic elution using purified water: acetonitrila (48:52 v/v), the flow rate was 0,8 mL/min and the injection volume was 20 µL. The column temperature was kept at 35 ºC and detection wavelength was set at 238 mn. The micellar electrokinetic chromatographic method was developed using a fused silica capillary column 30 cm (effective length) x 50 µm i.d, the electrolyte was constituted of 20 mmol L-1 tetraborate buffer solution: 30 mmol L-1 sodium dodecyl sulphate (SDS), pH 9.0 adjusted with 10% phosphoric acid: 12 % v/v acetonitrile. The injection time was 3 s at 20 mbar, the applied voltage was 30 kV and detection was set at 238 nm. The both methods were developed and validated according to ANVISA, ICH and US Pharmacopeia guidelines. Therefore, the proposed methods proved to be linear, precise, accurate and suitable for simultaneous quantitation of ezetimibe and simvastatin in solid pharmaceutical formulations.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-07-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.