• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.9.2017.tde-14122016-144958
Document
Auteur
Nom complet
Grazielle Prado Alexandre
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Santoro, Maria Ines Rocha Miritello (Président)
Felli, Veni Maria Andres
Matta, Vladi Olga Consigliere de
Mercuri, Lucildes Pita
Silva, Vânia Aparecida Blasques Bueno
Titre en portugais
Validação dos sistemas computadorizados empregados na determinação dos enantiômeros do nadolol e dos homólogos da ivermectina e da abamectina
Mots-clés en portugais
Abamectina
Cromatografia em fase líquida de alta eficiência
Dicroísmo circular
Eletroforese capilar
Ivermectina
Métodos analíticos
Nadolol
Preparações farmacêuticas
Validação
Resumé en portugais
O nadolol é um agente bloqueador de receptores β-adrenérgicos empregado principalmente, na "angina pectoris", hipertensão, certas arritmias cardíacas e no tratamento do glaucoma (SING, 2006). A ivermectina e a abamectina são fármacos que apresentam ação antiparasitária (SHOOP, 1995). Na presente pesquisa, a cromatografia em fase líquida de alta eficiência foi uma das técnicas estudadas para a quantificação dos enantiômeros do nadolol e dos homólogos presentes na abamectina e ivermectina. A versatilidade desta técnica reside no grande número de fases estacionárias existentes, as quais possibilitam análises, separações e determinações quantitativas de uma ampla gama de compostos com alta eficiência (Aquino Neto e Nunes, 2003). Para identificação dos enantiômeros do nadolol foi utilizado o dicroísmo circular que permite a determinação da configuração absoluta de enantiômeros (LIMA, 1997). Para os enantiômeros do nadolol e dos homólogos presentes na abamectina e na ivermectina também foram realizados testes para desenvolvimento de uma metodologia de quantificação por meio de uma técnica relativamente recente chamada de eletroforese capilar (EC), a qual tem alcançado desde sua introdução um rápido desenvolvimento e ampla aplicação na análise de fármacos em medicamentos (SANTORO, 2000). Para a comprovação da qualidade e segurança dos sistemas computadorizados dos equipamentos de cromatografia em fase líquida de alta eficiência (CLAE) e de eletroforese capilar (EC) foram efetuadas, neste trabalho, as respectivas validações. Após esta validação, pode-se confirmar o correto funcionamento de um software, e suas interações com o hardware, onde devem ser levados em consideração, dentre outros, os aspectos relacionados à infra-estrutura, segurança e manutenção de dados (AGÊNCIA NACIONAL DE VIGILÂNIA SANITÁRIA, 2010). As metodologias analíticas desenvolvidas a para quantificação do nadolol, abamectina e ivermectina por cromatografia em fase líquida de alta eficiência foram validadas. A validação analítica deve garantir, por meio de estudos experimentais, que o método atenda às exigências das aplicações analíticas, assegurando a confiabilidade dos resultados. Para tanto, o método deve apresentar especificidade, linearidade, intervalo, precisão, sensibilidade, limite de quantificação e detecção, exatidão, adequados à análise (AGÊNCIA NACIONAL DE VIGILÂNIA SANITÁRIA, 2003). Portanto, o objetivo proposto nesta pesquisa é primeiramente a validação dos sistemas computadorizados dos equipamentos de cromatografia em fase líquida de alta eficiência (CLAE) e de eletroforese capilar (EC). Para isto, serão desenvolvidos e validados os métodos analíticos de separação, identificação e quantificação dos enantiômeros do nadolol e dos homólogos presentes na abamectina e na ivermectina, em medicamentos, empregando as técnicas analíticas selecionadas.
Titre en anglais
Validation of the computer systems used in the determination of nadolol enantiomers and homologous of ivermectin and abamectin.
Mots-clés en anglais
Abamectin
Analytical methods
Capillary electrophoresis
Circular dichroism
High performance liquid chromatography
Ivermectin
Nadolol
Pharmaceutical preparations
Validation
Resumé en anglais
Nadolol is a blocking agent with activity in the β -adrenergic receptors. It is mainly used in angina, hypertension, certain heart arrhythmias and in the treatment of glaucoma (SING, 2006). Ivermectin and abamectin are drugs with antiparasitic activity (SHOOP, 1995). In the present research, high performance liquid chromatography is one of the techniques used in the quantification of the enantiomers of nadolol and homologues present in abamectin and ivermectin. The versatility of this technique and the large number of existing stationary phases, enables the separation and quantitative determination of a wide range of compounds with high efficiency (Aquino Neto e Nunes, 2003). For identification of the nadolol enantiomers, circular dichroism was used which allows the determination of the absolute configuration of the enantiomers (LIMA, 1997). Nadolol enantiomers and the homologues present in abamectin and ivermectin will be also quantified by capillary zone electrophoresis (CE), a separation technique relatively recent, which has achieved, since its introduction, a wide application in the analysis of drugs in pharmaceutical preparations (SANTORO, 2000). In order to assure the quality of the analytical results, the computer systems of the liquid chromatograph and capillary electrophoresis equipments, must be validated prior to the analytical methods validation. Computer systems validation is used to verify and confirm the proper operation of softwares, and their interactions with the hardwares, besides the infrastructure, safety and storage of data (AGÊNCIA NACIONAL DE VIGILÂNIA SANITÁRIA, 2010). The analytical methodologies developed for quantification of nadolol, abamectin, ivermectin by using high efficiency liquid chromatography and capillary electrophoresis were validated. The analytical methods validation should ensure, through experimental studies, that the method meets the requirements for analytical applications, ensuring the reliability of the results. Parameters like, specificity, linearity, range, accuracy, sensitivity, limits of detection and quantification and accuracy, must be determined (AGÊNCIA NACIONAL DE VIGILÂNIA SANITÁRIA, 2003). The objective of this study is to validate the computer systems of the high performance liquid chromatograph and capillary electrophoresis equipments and then to develop and validate analytical methods for separation, identification and quantification of nadolol enantiomers and the homologues of abamectin and ivermectin.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-02-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.