• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2011.tde-14092012-111612
Documento
Autor
Nombre completo
Cátia Panizzon Dal Curtivo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Chacra, Nádia Araci Bou (Presidente)
Taqueda, Maria Elena Santos
Tavares, Leoberto Costa
Título en portugués
Avaliação do processo de fabricação de comprimidos de Captopril (25 mg): aplicação da tecnologia analítica de processo e de ferramentas da qualidade e estatística
Palabras clave en portugués
Comprimidos
Espectroscopia de infravermelho próximo
Índices de capacidade
Tecnologia analítica de processo
Validação de processo
Validação do método
Resumen en portugués
As Boas Práticas de Fabricação de Medicamentos (BPFM) enfatizam que a indústria farmacêutica deve dirigir seus esforços no sentido de compreender a variação do processo, incluindo as fontes, o grau de variação e o impacto dessa variação nas características de qualidade do produto. O processo de fabricação de medicamentos tem apresentado significativas mudanças, em especial no que se refere à introdução de tecnologias analíticas que permitem o controle do processo em tempo real. A abordagem baseada na análise de risco e no novo Sistema de Qualidade Farmacêutica constitui ponto central das BPFM para o século XXI. Os órgãos regulatórios têm exigido da indústria farmacêutica sua adesão na melhoria contínua relativa ao desempenho de seus processos e, por consequência, na qualidade do produto. O objetivo do presente trabalho foi o desenvolvimento e validação de método analítico empregando espectroscopia no infravermelho próximo, assim como a avaliação do processo de fabricação de comprimidos de Captopril 25 mg, empregando abordagem racional-científica. Com referência à avaliação do processo, foram adotadas as seguintes ferramentas: análise de modos e efeitos de falhas (FMEA); gráficos de controle; índices de capacidade e análise de variância (ANOVA). A espectroscopia por infravermelho próximo (NIR) foi selecionada por apresentar maior rapidez na obtenção dos resultados, maior simplicidade na preparação das amostras, multiplicidade das análises a partir de uma única leitura e por apresentar característica não invasiva. Os resultados comprovaram a adequação dessa tecnologia na avaliação quantitativa do Captopril nas etapas de mistura de pós e de compressão. Os desvios padrão relativos na determinação da uniformidade de Captopril na mistura de pós e nos comprimidos empregando método no NIR foram, respectivamente 3,15 e 0,18%. No que se refere à avaliação da estabilidade e da capacidade do processo, as ferramentas adotadas permitiram a compreensão das fontes de variabilidade, assim como a determinação de seu grau, nas diferentes etapas do processo. Os índices de capacidade (CpK) relativos à uniformidade de Captopril (% p/v) na mistura de pós, ao peso médio do comprimido, à uniformidade de conteúdo e à % (p/v) dissolvida de Captopril, no ensaio de dissolução, foram 0,70, 1,94, 1,80 e 2,19, respectivamente.
Título en inglés
Manufacturing process evaluation of Captopril (25 mg) tablets: application of process analytical technology and quality tools and statistical
Palabras clave en inglés
Capability indices
Method validation
Near-infrared spectroscopy (NIR)
Process analytical technology (PAT)
Process validation
Tablets
Resumen en inglés
The Good Manufacturing Practices (GMP) for Medicinal Products point out that the pharmaceutical industry must direct efforts to understand the variation of the processes, including the sources, the level of variation and the variation impact on the process in characteristics of the product. The manufacturing process has shown meaningful changes, especially in the introduction of new analytical technologies that allow the process control in real time. The approach based on risk analyses and on the new Pharmaceutical Quality System is a central key for the GMP for the XXI century. The Regulatory Agencies have demanded the pharmaceutical industry to adhere the continuous improvement related to the performance of its processes and, consequently, the product quality. Thus, the present paper aimed the development and validation of the analytical method employing NIR spectroscopy as the assessment of manufacturing process of Captopril 25 mg tablets, using rational scientific approach. Regarding the process assessment, the following tools were adopted: analysis of failure modes and effects analysis (FMEA), control charts, capability indexes, as well as analysis of variance (ANOVA). The near-infrared spectroscopy was selected due to its greater speed in getting the results, simplicity in sample preparation, and multiplicity of analysis from a single reading and provide non-invasive feature. The results confirmed the suitability of this technology in quantitative assessment of Captopril on the steps of mixing powders and compression. The relative standard deviations for the determination of Captopril uniformity in the post mixtures and in the tablets employing NIR were 3,15 e 0,18%, respectively. In reference to the stability assessment and process capacity, the tools adopted permitted the understanding of the sources of variability, as well as the determination of their level in different phases of the process. The capacity indexes relating to Captopril uniformity (% p/v) in the powder mixture, the average weight of the tablet, the content uniformity and the % (p/v) dissolved Captopril, in the dissolution assay were 0,70, 1,94, 1,80 and 2,19, respectively.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-10-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.