Title in Portuguese
Detecção por raios-x de trincas de fadiga em juntas rebitadas de Glare®
Keywords in Portuguese
Fadiga
Junta rebitada
Laminado metal fibra
Material aeronáutico
Radiografia de raios-x
Abstract in Portuguese
Foi realizado um estudo comparativo da capacidade de duas variantes do método de radiografia por raios- X em detectar trincas de fadiga em juntas sobrepostas rebitadas de laminado híbrido metal-fibra Glare® de uso aeronáutico. Durante os ensaios mecânicos de fadiga sob amplitude constante de tensão, diversos corpos de prova rebitados foram periodicamente inspecionados por raios-X, em ambas as modalidades convencional e digital. Raios-X em filmes convencionais digital. Raios-X em filmes convencionais proporcionaram ótimo detalhamento de trincas nas juntas mecânicas, enquanto que as imagens geradas pela modalidade digital apresentaram qualidade muito inferior, prejudicando ou até mesmo impedindo a avaliação do grau de integridade estrutural das juntas rebitadas.
Title in English
X-ray inspection of fatigue cracks in riveted lap joints of Glare&trade
Keywords in English
Airframe material
Fatigue
Ffiber metal-laminate
Riveted lap joint
X-ray radiography
Abstract in English
A comparison is performed on the ability of two modalities of nondestructive X-ray radiography method in detecting fatigue cracks in riveted lap joints of aeronautical grade fiber-metal laminate Glare™. During constant amplitude loading in fatigue testing riveted specimens were periodically inspected using both the conventional and digital X-ray methodology. Conventional film X-ray modality provided high quality images of growing cracks in the mechanical joints, whereas digital radiography generated faulty images, which impaired or even prevented the structural integrity assessment of the riveted joints.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
HenriqueSoares_M.pdf (20.93 Mbytes)
Publishing Date
2008-04-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.