• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.88.2007.tde-01122014-112608
Documento
Autor
Nombre completo
Elys Raquel Andrade Ferreira
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Goncalves, Debora (Presidente)
Guimaraes, Francisco Eduardo Gontijo
Mascaro, Lucia Helena
Título en portugués
Filmes de polipirrol como matrizes para a imobilização da polifenol oxidase e aplicação como biossensores amperométricos na análise de compostos fenólicos
Palabras clave en portugués
Biosensores
Polifenol oxidase (PFO)
Polipirrol (PPI)
Resumen en portugués
Nesta dissertação, a polifenol oxidase (PFO) como extrato bruto de abacate (Persea americana) foi imobilizada em filmes de polipirrol (PPI) sintetizados eletroquimicamente utilizando o glutaraldeído (GA) como um agente de ligação entrecruzada. Os filmes PPI e PPI/PFO-GA foram caracterizados por eletroquímica, principalmente voltametria cíclica, sendo avaliadas a eletroatividade e a reversibilidade eletroquímica. A detecção de compostos fenólicos em soluções padrão foi feita por cronoamperometria, tendo um controle sobre a concentração dos compostos. O processo de transferência de massa foi monitorado com uma microbalança de cristal de quartzo eletroquímica. Os resultados indicaram uma boa reprodutibilidade das medidas na detecção dos compostos fenólicos. A estabilidade do biossensor em uma solução tampão manteve-se durante 27 dias, um resultado aceitável já que é encontrado na literatura um tempo de vida estável para sistemas semelhantes em tomo de 30 dias
Título en inglés
Polypyrrole film as matrix for the immobilization of polyphenol oxidase and application as amperometric biosensors in the analysis of phenolic
Palabras clave en inglés
Biosensors
Polyphenol oxidase (PPO)
Polypyrrole (PPY)
Resumen en inglés
In this dissertation, polyphenol oxidase (PPO) as crude extract of avocado (Persea americana) was immobilized on electrochemical1y synthesized polypyrrole (PPY) films using glutaraldehyde (GA) as a crosslinking agent. PPY and PPY/PPO-GA films were electrochemical1y characterized, mainly by cyclic voltametry, where electroactivity and electrochemical reversibility were evaluated. The detection of phenolic compounds in standard samples was made by chronoamperometry with a control over the compound concentration. The process of mass transfer was monitored with an electrochemical quartz crystal microbalance (EQCM). Our results indicated a good repeatability of the measurements for the detection of phenolic compounds. The stability of biosensor in a buffer solution has remained for 27 days, a result acceptable since it is found in the literature a time of life stable for similar systems around 30 days
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-12-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.