• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.85.2017.tde-29042022-111049
Documento
Autor
Nome completo
Graziele Cristiane Seco Coutinho
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2017
Orientador
Banca examinadora
Leal Neto, Ricardo Mendes (Presidente)
Ett, Gerhard
Leiva, Daniel Rodrigo
Título em português
Síntese de compósitos Mg-TiFe para armazenamento de hidrogênio
Palavras-chave em português
absorção
compósito
dessorção
hidrogênio
moagem
Resumo em português
Compósitos Mg - X %m. TiFe foram sintetizados por moagem de alta energia dos pós de MgH2 e TiFe em moinho planetário (X = 40, 50, 60) e moinho agitador (X = 40) sob atmosfera de argônio de alta pureza. Foi utilizado MgH2 comercial ao invés de pó de magnésio para se reduzir a aderência no recipiente de moagem e nas bolas. O pó de TiFe foi previamente produzido por moagem de alta energia a partir da mistura de pós TiH2 e Fe, seguido da reação de síntese a 600°C. Os compósitos moídos foram caracterizados por analise de DRX e MEV. O tempo de moagem foi investigado preliminarmente (X = 40) no moinho planetário (6 a 36 h). Notou-se uma dificuldade na redução do tamanho das partículas de TiFe, uma vez que estão envolvidas na matriz de MgH2. Uma intensa redução de partículas foi obtida utilizando o moinho agitador por 4 e 6 horas com adição de ciclohexano como agente controlador de processo. Não foram observadas reações entre o MgH2 e o composto intermetálico TiFe em nenhuma das amostras moídas. As medidas cinéticas e PCT de absorção de hidrogênio das amostras moídas foram conduzidas em um equipamento tipo Sievert à temperatura ambiente após a dessorção de hidrogênio à 350°C sob vácuo. As medidas PCT de dessorção foram conduzidas em um equipamento tipo Sievert em temperaturas de 270; 300; 370 e 400 °C. As maiores capacidades de absorção de hidrogênio foram observadas para as amostras moídas no moinho agitador (3,9 e 4% em massa) após 4 e 13h. Não se obteve dessorção de hidrogênio à temperatura ambiente. A dessorção de hidrogênio iniciou-se a partir da temperatura de 300 °C.
Título em inglês
Synthesis of Mg-TiFe composites for hydrogen storage
Palavras-chave em inglês
absorption
composite
desorption
hydrogen
milling
Resumo em inglês
Mg - X wt. % TiFe composites were synthesized by high-energy ball milling of the MgH2 and TiFe powders in a planetary (X = 40, 50, 60) and shaker mill (X = 40) under high-purity argon atmosphere. Commercial MgH2 instead of Mg powder was used in order to reduce adherence on the vial and balls. TiFe powder was previously produced by ball milling a mixture of TiH2 and Fe powders followed by a reaction synthesis at 600ºC. Milled composites samples were characterized by XRD and SEM analysis. Milling time was preliminary investigated (X = 40) in the planetary ball mill (6 to 36 h). TiFe particle size reduction was shown to be difficult since they are surrounded by MgH2 matrix. Strong particle reduction was obtained by using a shaker mill for 4 and 6 hours and adding cyclohexane as process control agent. No reaction between MgH2 and TiFe compound was observed in any milled sample. Hydrogen absorption kinetics and PCT measurements of the as-milled samples were conducted on a Sieverts' type apparatus at room temperature after hydrogen desorption at 350ºC under vacuum. The desorption PCT measurements were conducted on a Sieverts type apparatus at temperatures of 270 ° C; 300; 370 and 400 ° C. The higher hydrogen absorption capacities were observed for samples milled in the shaker mill (3.9 and 4wt. %) after 4 and 13 h. No hydrogen desorption was obtained at room temperature. The hydrogen desorption started from the temperature of 300 ° C.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2022-05-05
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.