Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2016.tde-09032016-091931
Documento
Autor
Nombre completo
Denise Trigilio Tavares
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Bustillos, José Oscar Willian Vega (Presidente)
Rossini, Edvaldo Luis
Taqueda, Maria Elena Santos
Título en portugués
Análise quantitativa de alcanolaminas e CO2 no processo de absorção química via espectroscopia no infravermelho
Palabras clave en portugués
alcanolaminas
CO2
curvas de calibração
infravermelho
Resumen en portugués
Em virtude da necessidade de se quantificar os carbamatos provenientes de processos de absorção química do gás CO2 por monoetanolamina (MEA) e dietanolamina (DEA), curvas analíticas por espectroscopia no infravermelho (IV) foram construídas visando à determinação do teor de carbamatos de MEA e DEA, além da quantificação de MEA, DEA e metildietanolamina (MDEA) em soluções puras e em misturas. O procedimento analítico compreendeu o preparo das amostras-padrão constituintes das curvas de calibração e suas quantificações com o emprego de técnicas instrumentais de referência titulação potenciométrica, pesagem e GC-FID. As amostras-padrão de aminas puras foram quantificadas por titulação potenciométrica, sendo possível a detecção exata do ponto de equivalência. As composições dos padrões analíticos de misturas foram estabelecidas segundo um diagrama triangular para misturas e o teor de cada componente foi determinado por gravimetria e GC-FID. Tanto a hidrólise quanto a degradação térmica dos carbamatos foram fatores que restringiram o emprego da titulação potenciométrica, HPLC-MS/MS e GC-FID como técnicas de referência em suas quantificações. Essas restrições, somadas ao fato de não haver disponibilidade comercial desses carbamatos, levaram ao uso da espectroscopia de RMN de 1H na determinação quantitativa. As curvas de calibração apresentaram ótimo ajuste dos valores preditos com relação aos de referência e erro máximo de predição de 0,594 %. Dois processos de absorção química do gás CO2 foram realizados em escala semipiloto e os resultados obtidos foram de 1,02 % e 0,98 % de CO2 absorvido por solução de MEA e DEA, respectivamente. Os mesmos processos foram simulados no software Aspen Plus, obtendo-se 1,18 % de CO2 absorvido por solução de MEA e 1,00 % por solução de DEA.
Título en inglés
Quantitative analysis of alkanolamines and CO2 in chemical absorption process by infrared spectroscopy
Palabras clave en inglés
alkanolamines
calibration curves
CO2
infrared
Resumen en inglés
Due to the need to quantify carbamates from the CO2 gas chemical absorption process by monoethanolamine (MEA) and diethanolamine (DEA), analytical curves by IR spectroscopy were obtained with the aim of quantifying MEA and DEA carbamates and MEA, DEA and methyldiethanolamine (MDEA) in pure solutions and mixtures. The analytical procedure considered the preparation of standard samples constituents of the calibration curves and their quantification using reference instrumental techniques potentiometric titration, gravimetry and GC-FID. The standard samples of pure amines were quantified by potentiometric titration, getting the accurate detection of the equivalence point. The compositions of the analytical standards of the mixtures were established according to a triangular diagram for mixtures and the content of each component was determined by gravimetry and GC-FID. The carbamate hidrolysis and its thermal degradation were factors that limited the use of potentiometric titration, HPLCMS/ MS and GC-FID as reference techniques in their quantitation. These restrictions, added to the fact of not having commercial availability of these carbamates, led the use of 1H NMR spectroscopy for the quantitative determination. The calibration curves resulted in an excellent adjustment of the expected values related to the reference values and maximum error of prediction of 0.594 %. Two chemical absorption processes of CO2 gas were performed in semi-pilot scale and the obtained results were of 1.02 % and 0.98 % of absorbed CO2 by MEA and DEA solutions, respectively. Both processes were simulated using Aspen Plus software, presenting 1.18 % of CO2 absorbed by MEA solution and 1.00 % by DEA solution.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2015TavaresAnalise.pdf (48.08 Mbytes)
Fecha de Publicación
2016-03-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.