• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2018.tde-08052018-112533
Documento
Autor
Nombre completo
Dayane Faria Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Sabundjian, Gaianê (Presidente)
Kuramoto, Renato Yoichi Ribeiro
Silva, Antonio Teixeira e
Título en portugués
Análise do comportamento da contenção do reator Angra 2 durante um acidente de base de projeto
Palabras clave en portugués
Angra 2
COCOSYS
contenção
LBLOCA
RELAP5
Resumen en portugués
Este trabalho visa verificar a integridade da contenção do reator de Angra 2, com uma abordagem mais realista, da possibilidade de conter todos os radionuclídeos gerados durante Acidentes de Perda de Refrigerante Primário por Grande Ruptura (Large Break Loss of Coolant Accident - LBLOCA). Além disso, essas informações são utilizadas para o cálculo mais realista do Pico de Temperatura do Encamisamento (PTE) da vareta mais realista do núcleo deste reator durante esse acidente. Os resultados desse estudo possibilitarão verificar a integridade da Planta após a ocorrência de acidentes considerados base de projeto. Alguns dos programas utilizados para analisar a contenção de uma usina nuclear são o RELAP5 e o COCOSYS. Esses códigos computacionais são ferramentas de análise que preveem as condições termohidráulicas dentro de um prédio de contenção de um reator refrigerado à água leve. A contenção da planta tipo Pressurized Water Reactor (PWR) é um edifício de concreto revestido internamente por metal e tem limites de pressão que devem ser respeitados durante a ocorrência de um acidente. Os dados de entradas necessários para esta simulação são: adição de massa e energia geradas do estudo de um acidente do tipo LBLOCA com o código RELAP5 da planta em questão. Os resultados da análise do comportamento da contenção da planta nuclear Angra 2 durante os acidentes base de projetos estudados rupturas do tipo guilhotina do circuito primário nas pernas fria e quente foram satisfatórios quando comparados com os apresentados no Relatório de Análise de Segurança (RFAS/A2) da planta e as distribuições de pressão ficaram bem abaixo do valor de pressão de projeto da contenção (6,3bar).
Título en inglés
Analysis of the behavior of the Angra 2 reactor containment during a design basis accident
Palabras clave en inglés
Angra 2
COCOSYS
containment
LBLOCA
RELAP5
Resumen en inglés
This work aims to verify the integrity of Angra 2 reactor containment by using a more realistic approach for the possibility of containing all radionuclides generated during a Large Break Loss of Coolant Accident (LBLOCA). In addition, this information is used for a more realistic calculation of the Peak Cladding Temperature (PCT) of the hottest area in the reactor during this accident. This study will contribute to the safety of the population from the surrounding areas after the occurrence of a design basis accident. Some of the programs used to analyze the containment of a nuclear plant are RELAP5 and COCOSYS. These computers codes are tools for analysis used for predicting the physical conditions and distributions of radionuclides inside a containment building following the release of material from the primary system in a light-water reactor accident. The containment of the type PWR plant is a concrete building coated internally with metal and has pressure limits to be respected during the occurrence of an accident. The simulation should be performed to ensure that the radionuclides originating from accidents in the plant are not released into the environment. The input data required for this simulation are: mass addition and energy generated from the simulation of an accident of the type Loss of Coolant Accident (LOCA) using RELAP5 code. The results of the analysis of the containment behavior of the Angra 2 nuclear plant during the design basis accidents studied - guillotine-type ruptures of the primary circuit in the cold and hot legs - were satisfactory when compared to those presented in the Final Safety Analysis Report (FSAR) of the plant; moreover, the pressure distributions were below the contention design pressure value (6.3bar).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2017SilvaAnalise.pdf (8.70 Mbytes)
Fecha de Publicación
2018-06-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.