• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2006.tde-22032012-171957
Documento
Autor
Nombre completo
Vitor Vivolo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Caldas, Linda Viola Ehlin (Presidente)
Costa, Paulo Roberto
Ghilardi Netto, Thomaz
Hamada, Margarida Mizue
Lejbman, Iuda Dawid Goldman Vel
Título en portugués
Desenvolvimento de um sistema de referência para determinação do equivalente de dose pessoal e da constância de feixes de radiação X
Palabras clave en portugués
câmaras de ionização
equivalente de dose pessoal
sistema Tandem
Resumen en portugués
Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10).
Título en inglés
Development of a reference system for the determination of the personal dose equivalent and the constancy of X-ray beams
Palabras clave en inglés
control quality
personal dose equivalent
X-ray beams
Resumen en inglés
A reference system for the determination of the personal dose equivalent, HP (10), and a quality control program of X-ray equipments used in radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, HP (10), was established.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-04-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.