Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2015.tde-20072015-095035
Document
Auteur
Nom complet
Eduardo Santana de Moura
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Zeituni, Carlos Alberto (Président)
Pellizzon, Antônio Cássio Assis
Ros, Renato Assenci
Rostelato, Maria Elisa Chuery Martins
Yoriyaz, Hélio
Titre en portugais
Desenvolvimento de um objeto simulador para investigação de heterogeneidades em braquiterapia de alta taxa de dose
Mots-clés en portugais
alta taxa de dose
braquiterapia
dosimetria
Resumé en portugais
A braquiterapia de alta taxa de dose é uma das modalidades mais utilizadas em braquiterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram a braquiterapia de alta taxa de dose uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente, ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heterogeneidades dos pacientes, tais como: tecidos e órgãos com composições diferentes da água (meio de referência em radioterapia), contorno do paciente individualizado, introdução de aplicadores, dentre outros. Tais avanços demandam o controle de qualidade destas ferramentas, com objetivo de assegurar que todo o processo de tratamento seja satisfatório e acurado. Até o momento, a comunidade carece de um sistema experimental capaz de avaliar, considerando os níveis de incerteza, se os sistemas de planejamento computadorizados são aptos a considerar a heterogeneidade dos tratamentos. Neste trabalho, apresentamos o desenvolvimento de medidas experimentais em um objeto simulador, com capacidade de mensurar as diferenças introduzidas pela heterogeneidade por meio de três técnicas dosimétricas experimentais: termoluminescência, filmes radiocrômicos e ionométrica. Os resultados experimentais foram comparados com as simulações de Monte Carlo e com um sistema de planejamento computadorizado comercial, apto a realizar correções de heterogeneidade em braquiterapia. Discutimos as principais etapas de desenvolvimento deste objeto simulador, seus resultados experimentais e as comparações com os demais sistemas. As conclusões e as etapas futuras deste projeto também são apresentadas.
Titre en anglais
Development of a phantom for investigations with heterogeneties in high-dose-rate brachytherapy
Mots-clés en anglais
brachytherapy
dosimetry
high dose rate
Resumé en anglais
High dose rate brachytherapy is one of the most widely used modalities in brachytherapy for cancer treatment The various technological advances and the development of treatment techniques have made high dose rate brachytherapy as one of the state of the art methods for the treatment of some cancers. Part of this progress is credited to the improvement in the accuracy and absorbed dose prescription recommended to patients over the years. This advance currently allows the possibility of performing dosimetric calculations, by means of computerized planning systems, considering the heterogeneity of patients, such as: tissues and organs with different water compositions (reference medium in radiotherapy), individualized patient's contour and introduction of applicators, among others. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Nowadays, the community needs an experimental system capable of evaluating, since the uncertainty levels if the computerized planning systems are able to consider the heterogeneity of treatments. In this project, we present the development of experimental measurements into a phantom, capable of measuring the differences introduced by heterogeneity through three experimental dosimetric techniques: thermoluminescence, radiochromic films and ionometric. The experimental results were compared with the Monte Carlo simulations and a commercial treatment planning system able to perform correction of heterogeneity in brachytherapy. We discuss the main stages of development of this phantom, their experimental results and comparisons with other systems. The conclusions and future steps to complete this project are also presented.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-07-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.