Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2020.tde-16092020-133045
Documento
Autor
Nombre completo
Fabrício Maia Torres Alves
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2020
Director
Tribunal
Caldas, Linda Viola Ehlin (Presidente)
Faria, Juliano Ferreira
Pinto, Teresa Cristina Nathan Outeiro
Título en portugués
Determinação da dose em pacientes submetidos a exames de tomografia computadorizada de abdome em um serviço de radiologia e diagnóstico por imagem
Palabras clave en portugués
abdome
dose
estimativa de dose específica de tamanho
tomografia computadorizada
Resumen en portugués
A incorporação de novas tecnologias nos últimos anos proporcionou um aumento expressivo no número de exames de tomografia computadorizada (TC) realizados no mundo e no Brasil e consequentemente seus efeitos deletérios relacionados à radiação ionizante. O objetivo foi verificar as doses dos exames de tomografia computadorizada do abdome realizados em um serviço de radiologia e diagnóstico por imagem, para determinar as ações técnicas que visam diminuí-las, bem como suas consequências. Foram analisados os relatórios de dose (emitidos automaticamente pelo próprio aparelho) dos exames de TC de abdome realizados no ano de 2018. As doses estimadas dos exames foram correlacionadas com a indicação clínica, de acordo com o pedido médico, anexado ao cadastro do paciente e ao número de fases realizadas em cada exame. Os resultados dos indicadores avaliados dos exames estavam dentro dos níveis de referência recomendados pela American College of Radiology. Em todas as indicações clínicas foi possível observar uma variabilidade grande no número de fases executadas. Foi possível observar a urgente necessidade de se readequar e padronizar os protocolos de exames dirigidos para a suspeita clínica, permitindo o uso racional com imediata redução no número de fases realizadas e consequentemente minimizar a dose que os pacientes recebem na realização destes exames.
Título en inglés
Determination of dose in patients submitted to abdome computed tomography examinations in a radiology and diagnostic image service
Palabras clave en inglés
abdomen
computed tomography
dose
size specific dose estimate
Resumen en inglés
The incorporation of new technologies in recent years has led to a significant increase in the number of computed tomography (CT) exams performed in the world and in Brazil and, consequently, their deleterious effects related to ionizing radiation. The objective was to verify the doses of abdominal computed tomography exams performed in a radiology and diagnostic imaging department to determine the technical actions that aim to decrease them, as well as their consequences. The dose reports (automatically issued by the device) of the abdominal CT examinations performed in 2018 were analyzed. The estimated doses of the examinations were correlated with the clinical indication, according to the medical request, attached to the records of the patients and the number of phases performed in each exam. The results of the assessed indicators were within the reference levels recommended by the American College of Radiology. In all clinical indications, it was possible to observe a great variability in the number of phases performed. It was possible to observe the urgent need to readjust and standardize the examination protocols aimed at clinical suspicion, allowing for rational use with immediate reduction in the number of phases performed, and consequently minimizing the dose that patients receive during these exams.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-09-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.