• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2017.tde-11082017-090607
Documento
Autor
Nombre completo
Lucas Rodrigues dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Potiens, Maria da Penha Albuquerque (Presidente)
Caldas, Linda Viola Ehlin
Pinto, Teresa Cristina Nathan Outeiro
Santos, William de Souza
Vivolo, Vitor
Título en portugués
Desenvolvimento de um protocolo de calibração utilizando espectrometria e simulação matemática, em feixes padrões de raios x
Palabras clave en portugués
coeficiente de calibração
espectrometria
função resposta
kerma
simulação pelo método de Monte Carlo
Resumen en portugués
A calibração, por definição, é o processo pelo qual se estabelece uma relação entre valores de medição de um padrão, com as suas respectivas incertezas, e as indicações com as incertezas associadas do instrumento de medição a ser calibrado. Um protocolo de calibração descreve a metodologia a ser aplicada em um processo de calibração. O método escolhido para a obtenção deste protocolo foi o da espectrometria de feixe de raios X associada à simulação pelo método de Monte Carlo, fundamentado no fato de que ambos são considerados métodos absolutos na determinação de parâmetros de feixes de radiação. Neste trabalho foi utilizado o método de Monte Carlo utilizado para obter a função resposta do detector utilizada para a correção dos espectros obtidos do feixe primário de radiação X; deste modo foram calculadas as taxas de kerma destes feixes e comparadas aos valores obtidos com as câmaras de ionização padrão secundário do Laboratório de Calibração de Instrumentos do IPEN (LCI/IPEN). Foram obtidos os coeficientes de calibração para o sistema padrão com diferenças em relação ao fornecido pelo laboratório primário entre 1,3% e 15,3%. Os resultados obtidos indicaram a viabilidade do estabelecimento deste protocolo de calibração utilizando a espectrometria como padrão de referência, com incertezas relativas de 0,62% para k=1. As incertezas associadas ao método proposto foram satisfatórias, para um laboratório padrão secundário e comparáveis a um laboratório primário.
Título en inglés
Development of a calibration protocol using spectrometry and mathematical simulation, in x ray standard beams
Palabras clave en inglés
coefficient of calibration
kerma
response function
simulation by the Monte Carlo method
spectrometry
Resumen en inglés
Calibration, by definition, is the process that establishes a relation between the measurement values of a standard, with their respective uncertainties, and the indications with the associated uncertainties of an instrument to be calibrated. A calibration protocol describes the methodology to be applied during the calibration process. The chosen method to obtain this protocol was the use of the X-ray beam spectrometry associated with Monte Carlo mathematical simulation, based on the fact that both are considered primary methods for x radiation beams parameters determination. The work consists in obtaining the detector response function using the Monte Carlo method for the correction of the X radiation primary beam spectra obtained. After that, the kerma rates values were calculated and compared to those obtained with the secondary standard ionization chambers of the Calibration Laboratory of IPEN. The calibration coefficients for the standard ionization chambers were found with differences from that provided by the primary laboratory between 1.3% and 15.31%. The results indicated the feasibility of establishing a protocol for the calibration of instruments using spectrometry as a reference standard, with relative uncertainties of 0.62% for k = 1. The uncertainties associated with the proposed method were satisfactory for a secondary standard laboratory and comparable to a primary laboratory.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-09-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.