• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2012.tde-09122013-140708
Documento
Autor
Nombre completo
Maíra Goes Nunes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Rodrigues, Letícia Lucente Campos (Presidente)
Hamada, Margarida Mizue
Ludwig, Zélia Maria da Costa
Silva, Teresinha de Moraes da
Teixeira, Maria Inês
Título en portugués
Desenvolvimento do dosímetro termoluminescente de CaSO4:Ce, Eu para a monitoração individual e a dosimetria clínica de fótons e elétrons
Palabras clave en portugués
dosimetria
monitoração individual externa
sulfato de cálcio
termoluminescência
terras raras
Resumen en portugués
Detectores de sulfato de cálcio ativado com cério IV e európio III utilizando o politetrafluoretileno (PTFE, Teflon®) free-flow como aglutinante (CaSO4:Ce,Eu + Teflon®) foram produzidos pelo método da estampagem, desenvolvido em colaboração com a empresa Tecnoflon, a partir de cristais crescidos de acordo com uma nova variação da rota da evaporação lenta, também apresentada nesse trabalho, com as concentrações de 0,16 mol% de Eu3+ e de 0,15 mol% de Ce4+ na solução ácida precursora. O modelo de dosímetro pessoal desenvolvido consiste em cinco detectores aderidos a um cartão de 30 x 48 mm de cloreto de polivinila (PVC) 95% opaco à luz na faixa do espectro eletromagnético que vai do infravermelho ao ultravioleta, idêntico aos cartões de identificação utilizados no IPEN, por uma tira de 10 x 35 mm de filme adesivo do mesmo material e foi submetido aos testes de aceitação descritos no regulamento técnico IRD-RT Nº 002.01/95, Desempenho de Sistemas de Monitoração Individual Critérios e Condições, sendo aprovado em todos os testes. Para a dosimetria clínica, os próprios detectores foram considerados dosímetros termoluminescentes e submetidos aos testes de aceitação descritos no código de práticas da Agência Internacional de Energia Atômica Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adotado como protocolo de dosimetria pela maioria dos hospitais, sendo igualmente aprovados nesses testes. Os dosímetros desenvolvidos podem ser utilizados para a monitoração individual externa e para dosimetria clínica, apresentando a diferenciação do tipo e da energia da radiação com que foram irradiados e a redução de custos como as principais vantagens em relação aos dosímetros termoluminescentes atualmente utilizados nessas aplicações.
Título en inglés
Development of CaSO4:Ce,Eu thermoluminescent dosimeters for individual monitoring for external exposures and clinical dosimetry
Palabras clave en inglés
calcium sulfate
dosimetry
individual monitoring of external exposure
rare earths
thermoluminescence
Resumen en inglés
Calcium sulphate activated with cerium IV and europium III using the free-flow polytetrafluoroethylene (PTFE, Teflon®) as bonder were produced by the stamping method, developed by the collaboration of Tecnoflon industries, from crystals growth according to a new variation of the slow evaporation method, also described in this study, with Eu3+ and Ce4+ concentrations of respectively 0.15 mol% and 0.16 mol% in the precursory acid solution. The developed personal dosimeter consist of five detectors adhered to a 30 x 48 mm polyvinyl chloride (PVC) card 95% mat to light in the infrared to ultraviolet wavelengths, identical to the access cards used by IPEN staff, by a 10 x 35 mm adhesive strip of the same material and it passed the acceptance tests required by Brazilian national regulatory committee for appliance in individual monitoring of external exposure services. The own detector is considered a dosimeter as far as clinical dosimetry is concerned and it passed the acceptance tests suggested by the International Atomic Energy Agency in the Technical Report Series Nº 398, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water, [TRS-398, IAEA, 2000] adopted as the dosimetry protocol by most hospitals. Hence, the developed dosimeters can be applied in the individual monitoring for external exposure and in the clinical dosimetry, having the radiation type and energy differentiation and the cost reduction as the key advantages over the currently used thermoluminescent dosimeters in such applications.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-01-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.